VCZAS1100/U - 2-way 1 in. sweat VC valve assembly for hydronic with 6.6 Cv and linear flow - Quad Industry GmbH

Àðòèêóë: VCZAS1100/U
Íàèìåíîâàíèå: 2-way 1 in. sweat VC valve assembly for hydronic with 6.6 Cv and linear flow
Ïðîèçâîäèòåëü: Honeywell


Overview

The TB7200 Series PI thermostat is available in BACnetî MS/TP and ZigBeeî wireless protocols and integrates into a WEBs-AX building automation system. Used with hydronic reheat valve control and pressure dependent VAV with or without local reheat.

Features

  • Available in BACnet MS/TP and ZigBee wireless protocols
  • Fully integrated advanced occupancy functionality with a PIR cover provides energy savings opportunity on select models, all other models are PIR ready and can have an optional occupancy sensor cover added at any time
  • Pre-configured sequences of operation means one model meets more application needs
  • Password protection to minimize parameter tampering
  • Four levels of keypad lockout to limit access to change user parameters
  • Available in 24 Vac on/off, floating or 0-10 Vdc analog control to meet advanced applications requirements
  • Three configurable inputs for monitoring and advanced functions
  • SPST auxiliary output that can be used for lighting or reheat
  • All wiring connections are made to removable terminal blocks simplifying installation.

Product Specifications

Application
Zoning Modulating with Reheat
Dimensions (in.)
5 in. high x 3 2/5 in. wide x 1 3/20 in. deep
Dimensions (mm)
125 mm high x 86 mm wide x 29 mm deep
Includes
Remote Temperature Sensor Input, 2 Digital Inputs, 1 Universal Input, 1 Aux Output
Used With
Compatible with WEBs-AX
Item Type
Product
Mounting
Vertical
Frequency
50 Hz, 60 Hz
Operating Humidity Range (% RH)
0 to 95% RH, non-condensing
Supply Voltage
24 Vac with range from 19 to 30 Vac
Switch Positions (System)
OFF-HEAT-COOL-AUTO
Switch Positions (Fan)
HI-MED-LOW-AUTO-OFF
Operating Temperature Range (F)
32 F to 122 F
Operating Temperature Range (C)
0 C to 50 C
Network Communications
BACnet MS/TP
Output
2 0 - 10 Vdc +1 Aux
Throttling Range (F)
3 F to 10 F
Throttling Range (C)
1.7 C to 5.6 C
Color
White
Output Signal
0 - 10 Vdc
Display
LCD
Changeover
Manual/Auto
Setting Temperature Range (F)
Heating: 40 F to 90 F, Cooling: 54 F to 100 F
Setting Temperature Range (C)
Heating: 4.5 C to 32 C, Cooling: 12.0 C to 37.5 C
Occupancy Sensor
Onboard PIR occupancy sensor cover
Output Signal Burden
0 - 10 Vdc into 2k Ohm resistance min.

Marketing Collateral

Sales/Promotional Materials-Communicating Thermostats Quick Selection Guide

Owners Manual

Operator/Owner Materials-ZigBee Wireless Survey Toolkit for TB7200/TB7300/TB7600 Series Thermostats

Wiring-Wiring example of single remote room sensor

Wiring-Wiring examples of 3 remote room sensors for averaging applications

Wiring-Wiring example of single remote room sensor

Wiring-Wiring examples of 2 remote room sensors for averaging applications

Wiring-Wiring examples of 3 remote room sensors for averaging applications

Wiring-Floor plan with proposed thermostats to be installed

Dimension-TB7200 Thermostat dimensions

Dimension-TB7300 Series thermostat dimensions

Technical Documents

Product Data and Specifications-Communicating Zone Thermostats

Installation Materials-Wireless Communication Card for TB7200/7300/7600 Series Communicating Thermostats

Installation Materials-Wireless Repeater for TB7200/7300/7600 Series Wireless Thermostats

Product Data and Specifications-Communicating Fan Coil Thermostats

Maintenance/Product Reference Materials-Wireless Installation Integration Reference Guide for TB7200/TB7300/TB7600 Series Thermostats

Maintenance/Product Reference Materials-BACnet Integration Manual for TB7200 and TB7300 Series Thermostats

Installation Materials-Communicating Fan Coil Thermostats, 24 VAC/for Commercial and lodging HVAC Applications

Installation Materials-Communicating Zone Thermostats

Application Guides-PIR Application Guide for TB7200 and TB7300 Series Thermostats

Maintenance/Product Reference Materials-Zoning Communicating Thermostats BACnet Protocol Implementation Conformance Statement

Maintenance/Product Reference Materials-Communicating Thermostats

Application Guides-Thermostat PIR Application Guide

Product Data and Specifications-Communicating RTU/Heat Pump Thermostats

Maintenance/Product Reference Materials-BACnet Integration Manual for TB7600 Series Thermostats

Product Data and Specifications-Communicating RTU Thermostats with Humidity Control

Installation Materials-Communicating RTU/Heat Pump Thermostats for Commercial HVAC applications

Installation Materials-Communicating RTU/Heat Pump Thermostats with Humidity Control

 



Íàçàä â ðàçäåë