| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
3VH1332-2MK11-0BB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2MK11-0BB4 |--| 3VH13322MK110BB4
|
Siemens
|
|
3VH1332-2MK16-0BB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2MK16-0BB4 |--| 3VH13322MK160BB4
|
Siemens
|
|
3VH1332-1MK10-0HF0
|
SIKUFEST STARTER COMBINATION 400V AC, 2.2KW SETTING RANGE 4.00 TO 6.00A TYPE OF CORDINATION 2 TEST CURRRENT R AC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 110V 50HZ/AC 132V 60HZ |--| 3VH1332-1MK10-0HF0 |--| 3VH13321MK100HF0
|
Siemens
|
|
3VH1332-1MK16-0AF0
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 110V 50HZ/AC 132V 60HZ |--| 3VH1332-1MK16-0AF0 |--| 3VH13321MK160AF0
|
Siemens
|
|
3VH1332-2MK11-0AP0
|
SIKUFEST STARTER COMBINATION FOR REVERSING 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-2MK11-0AP0 |--| 3VH13322MK110AP0
|
Siemens
|
|
3VH1332-1MK14-0JB4
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-1MK14-0JB4 |--| 3VH13321MK140JB4
|
Siemens
|
|
3VH1332-2MK14-0BB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 40MM SYSTEM 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2MK14-0BB4 |--| 3VH13322MK140BB4
|
Siemens
|
|
3VH1332-2MK16-0AP0
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-2MK16-0AP0 |--| 3VH13322MK160AP0
|
Siemens
|
|
3VH1332-1MK14-0BB4
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-1MK14-0BB4 |--| 3VH13321MK140BB4
|
Siemens
|
|
3VH1332-2MK16-0JB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2MK16-0JB4 |--| 3VH13322MK160JB4
|
Siemens
|
|
3VH1332-1MK16-0AV0
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 400/380V 50HZ, 480/460V 60HZ |--| 3VH1332-1MK16-0AV0 |--| 3VH13321MK160AV0
|
Siemens
|
|
3VH1332-1MK16-0AU0
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 240V 50HZ/AC 288V 60HZ |--| 3VH1332-1MK16-0AU0 |--| 3VH13321MK160AU0
|
Siemens
|
|
3VH1332-2ML06-0JB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 3 TO 4 KW SETTING RANGE 6.00 TO 10.0A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION WITH FITTED VARISTOR WITHOUT AUXILIARY CONTACTS (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2ML06-0JB4 |--| 3VH13322ML060JB4
|
Siemens
|
|
3VH1332-2ML11-0AP0
|
SIKUFEST STARTER COMBINATION FOR REVERSING 400V AC, 3 TO 4 KW SETTING RANGE 6.00 TO 10.0A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-2ML11-0AP0 |--| 3VH13322ML110AP0
|
Siemens
|
|
3VH1332-2MK16-0HP0
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 2,20KW SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-2MK16-0HP0 |--| 3VH13322MK160HP0
|
Siemens
|
|
3VH1332-1MK16-0AN1
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 220V 60HZ/AC 183V 50HZ |--| 3VH1332-1MK16-0AN1 |--| 3VH13321MK160AN1
|
Siemens
|
|
3VH1332-1MK16-0BB4
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-1MK16-0BB4 |--| 3VH13321MK160BB4
|
Siemens
|
|
3VH1332-2ML14-0AP0
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 40MM SYSTEM 400V AC, 3 TO 4 KW SETTING RANGE 6.00 TO 10.0A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-2ML14-0AP0 |--| 3VH13322ML140AP0
|
Siemens
|
|
3VH1332-1MK16-0AP0
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-1MK16-0AP0 |--| 3VH13321MK160AP0
|
Siemens
|
|
3VH1332-1MK16-0BF4
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 110V |--| 3VH1332-1MK16-0BF4 |--| 3VH13321MK160BF4
|
Siemens
|
|
3VH1332-2ML16-0JB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 3 TO 4 KW SETTING RANGE 6.00 TO 10.0A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2ML16-0JB4 |--| 3VH13322ML160JB4
|
Siemens
|
|
3VH1332-1MK16-0BG4
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 125V |--| 3VH1332-1MK16-0BG4 |--| 3VH13321MK160BG4
|
Siemens
|
|
3VH1332-1MK16-0HP0
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-1MK16-0HP0 |--| 3VH13321MK160HP0
|
Siemens
|
|
3VH1332-2ML11-0JB4
|
SIKUFEST STARTER COMBINATION FOR REVERSING 400V AC, 3 TO 4 KW SETTING RANGE 6.00 TO 10.0A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-2ML11-0JB4 |--| 3VH13322ML110JB4
|
Siemens
|
|
3VH1332-2ML16-0AP0
|
SIKUFEST STARTER COMBINATION FOR REVERSING ON 60MM SYSTEM 400V AC, 3 TO 4 KW SETTING RANGE 6.00 TO 10.0A TYPE OF COORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1332-2ML16-0AP0 |--| 3VH13322ML160AP0
|
Siemens
|
|
3VH1332-1MK16-0JB4
|
SIKUFEST STARTER COMBINATION COMBINATION ON 60MM SYSTEM 400V AC, 2.20 SETTING RANGE 4.00 TO 6.00A TYPE OF COORDINATION 2 TEST CURRENT R DC OPERATION WITH FITTED VARISTOR W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) WITHOUT AUXILIARY CONTACTS (FOR CONTACTOR) DC 24V |--| 3VH1332-1MK16-0JB4 |--| 3VH13321MK160JB4
|
Siemens
|
|
3VH1342-1MH00-1AU0
|
MOT.STARTER ASSEMBLY SIKUFEST AC 400V, 0.75KW SETTING RANGE 1.6 TO 2.4A TYPE OF CO-ORDINATION 2 RATED SHORT-CIRC.CURR.IQ=50KA AC OPERATION WITHOUT AUXILIARY CONTACTS (FOR CIRCUIT-BREAKER) W.AUXILIARY CONTACTS 1NO+1NC (FOR CONTACTOR) AC 240V 50HZ/AC 288V 60HZ |--| 3VH1342-1MH00-1AU0 |--| 3VH13421MH001AU0
|
Siemens
|
|
3VH1342-1MK10-5AP0
|
SIKUFEST STARTER COMBINATION 400V AC, 2..2KW SETTING RANGE 4 TO 6 A TYPE OF CORDINATION 2 TEST CURRENT R AC OPERATION W.AUXILIARY CONTACTS 1NO+1NC (FOR CIRCUIT-BREAKER) W.AUXILIARY CONTACTS 2NO+2NC (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1342-1MK10-5AP0 |--| 3VH13421MK105AP0
|
Siemens
|
|
3VH1342-1MJ00-1AP0
|
SIKUFEST STARTER COMBINATION 400V AC, 1.10 TO 1.50KW SETTING RANGE 2.40 TO 4.00A TYPE OF CORDINATION 2 TEST CURRENT R AC OPERATION WITHOUT AUXILIARY CONTACTS (FOR CIRCUIT-BREAKER) W.AUXILIARY CONTACTS 1NO+1NC (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1342-1MJ00-1AP0 |--| 3VH13421MJ001AP0
|
Siemens
|
|
3VH1342-1MK20-5AP0
|
SIKUFEST STARTER COMBINATION 400V AC, 2..2KW SETTING RANGE 4 TO 6 A TYPE OF CORDINATION 2 TEST CURRENT R AC OPERATION WITH AUXILIARY CONTACTS 2NO (FOR CIRCUIT-BREAKER) W.AUXILIARY CONTACTS 2NO+2NC (FOR CONTACTOR) AC 230/220V 50HZ, 276/264V 60HZ |--| 3VH1342-1MK20-5AP0 |--| 3VH13421MK205AP0
|
Siemens
|