| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
A1D00119780
|
4 GANTRY SMD PLACEMENT STATION SIPLACE X4 WITH MAXIMUM BENCHMA RK PLACEMENT RATE OF 90.000 CPH . ONE OF THE FOLLOWING CONFIGU RATIONS MUST BE SELECTED : - 7 7119780 SIPLACE X4 WITH SOFTWAR E 60X - 77119781 SIPLACE X4-A W ITH SOFTWARE 70X EQUIPPED WITH 4 C+P HEADS (20 OR CPP) - 77119 782 SIPLACE X4-B WITH SOFTWARE 70X EQUIPPED WITH 3 C+P HEADS ( 20 OR CPP) AND 1 TWIN HEAD - 77 119783 SIPLACE X4-C WITH SOFTWA RE 70X EQUIPPED WITH 2 C+P HEAD S (20 OR CPP) AND 2 TWIN HEADS - 77119784 SIPLACE X4-D WITH SO FTWARE 70X EQUIPPED WITH 1 C+P HEADS (20 OR CPP) AND 3 TWIN HE ADS - 77119785 SIPLACE X4-E WIT H SOFTWARE 70X EQUIPPED WITH 4 |--| A1D00119780
|
Siemens
|
|
A1D00116921-04
|
SIPLACE SETUP CENTER BASIC PACK AGE. THIS SOFTWARE PACKAGE FOR BASICSETUP VERIFICATION IS REQ UIRED ONE TIME PER FACTORY FOR SIPLACE C/S/F,HS-XX,HFX,XX. THE FOLLOWING SOFTWARE COMPONENTS ARE INCLUDED:BASICSOFTWARE PACK AGE (1 PCS), SETUP CONTROL DATA BASE (MSDE) (1 PCS). |--| A1D00116921-04 |--| A1D0011692104
|
Siemens
|
|
A1D00119779
|
HIGH RESOLUTION DIGITAL COMPONE NT CAMERA FOR THE 12-SEGMENT CO LLECT AND PLACE HEAD IN SIPLACE X/D-SERIES. EXCHANGE BETWEEN S TANDARD DIGITAL COMPONENT CAMER A. THE STANDARD DIGITAL COMPONE NT CAMERA IS THEN NOT PART OF D ELIVERY. THE COMPONENT RANGE FR OM 0.6MM X 0.3MM (0201) TO 18.7 MM X 18.7MM CAN BE PLACED. THE SMALLEST BUMP DIAMETER IS 140UM . THE MIN. LEAD / BUMPPITCH 300 UM / 250UM. THIS ITEM NUMBER CA N ONLY ORDERED IN COMBINATION W ITH SIPLACE X/D-SERIES. IT CANN OT BE ORDERED SEPERATELY. |--| A1D00119779
|
Siemens
|
|
A1D00116927
|
THE WLAN CLIENT MODULE (HARDWAR E) IS NEEDED FOR THE COMMUNICAT ON BETWEEN THE SIPLACE LAN AND THE WIRELESS (WLAN) SCANNER NET WORK. NOTE: THE NUMBER OF WLAN CLIENT MODULES HAS TO BE DETERM INED IN A FACTORY PRIOR TO THE INSTALL. |--| A1D00116927
|
Siemens
|
|
A1D00116924
|
THIS WLAN ACCESS POINT (HARDWAR E) IS NEEDED FOR THE WIRELESS C OMMUNICATION BETWEEN SETUP CENT ER PC AND ONE OR MORE POCKET PC SCANNER. NOTE: THE NUMBER OF W LAN ACCESS POINTS HAS TO BE DET ERMINED IN A FACTORY PRIOR TO T HE INSTALL. |--| A1D00116924
|
Siemens
|
|
A1D00119781
|
EXTERNAL POWER SUPPLY FOR FEEDE R CHANGEOVER TABLES SIPLACE D1/ D2 (ITEM NO. 119822), SIPLACE D 3 AND SIPLACE HF/X-SERIES (ITEM NO. 119622). THE ENCLOSED CONN ECTING CABLE (BETWEEN POWER SUP PLY AND CHANGEOVER TABLE) PERMI TS USAGE WITH CHANGEOVER TABLES SIPLACE D3/HF (ITEM NO. 119622 ). MAIN VOLTAGE 88 - 264VAC. IN CLUSIVE 2 MAIN PLUGS, 2M LONG ( EU AND US VERSION), 1 PNEUMATIC CONNECTOR AS WELL AS 2 FUSES. |--| A1D00119781
|
Siemens
|
|
A1D00116931
|
THIS OPTION FOR THE X-SERIES CO NTAINS A CANBUS-CARD WITH CANBU S-CABLES AND IS REQUIRED FOR CO MMUNICATION BETWEEN ESS-PC (116 366 SIPLACE PRO DESKTOP HARDWAR E + OS) AND ESS-DOCKING STATION . ESS-DOCKING STATION FOR CHANG EOVER TABLE X-SERIES (116933).E SS (EXTERNE SETUP STATION).ESS- PC AND ESS-DOCKING STATION HAS TO BE ORDERED SEPARATELY. ).ESS-PC AND ESS-DOCKING STATIO N HAS TO BE ORDERED SEPARATELY. |--| A1D00116931
|
Siemens
|
|
A1D00116923
|
THIS RF SCANNER (DATALOGIC M101 ) IS NEEDED FOR THE COMPONENT S ETUP VERIFICATION WITH THE SIPL ACE SETUP CENTER BASIC PACKAGE, AT LEAST ONE TIME PER LINE. |--| A1D00116923
|
Siemens
|
|
A1D00119788-01
|
THE OFFLINE TEACH STATION SIPLA CE X/D-SERIES SIMPLIFIES THE PR OCESS OFCREATING VISION FILES ( GFS) OFFLINE. THE COMPONENT VIS ION FILE ISCREATED USING THE AC TUAL COMPONENT WHICH IS IMAGED PROCESSED USING THE COMPONENT C AMERA. FOLLOWING THIS THE COMPO NENT DESCRIPTION (GF) ISEXPORTE D TO THE SIPLACE PRO DATABASE. THE OFFLINE TEACH STATION COMES WITH THE COMPUTER, ADJUSTABLE C OMPONENT SUPPORT PLATE, CAMERA MOUNTINGTOWER, COMPONENT VISION CAMERA, DOCUMENTATION AND SOFT WARE PACKAGE. THECAMERA TYPE IS CONFIGURED ACCORDING TO CUSTOM ER REQUIREMENTS. ALLSIPLACE X/D -SERIES COMPONENT CAMERAS ARE A VAILABLE:C+P 20 CAMERA,C+P 12CA |--| A1D00119788-01 |--| A1D0011978801
|
Siemens
|
|
A1D00116933
|
DOCKING STATION FOR PROVISION O F AN INFRASTRUCTURE FOR COMMUNI CATION BETWEEN THE PC OF THE SE TUP CENTER AND THE X-FEEDER MOD ULES. STAND ALONE OPERATION ALL OWS THE X-FEEDERS TO BE SUPPLIE D WITH POWER. CAN BE SET TO THE SMEMA HEIGHTS 830/ 900/ 930/ 9 50 MM. LINE VOLTAGE: 88-264V. C OMPRESSED AIR PRESSURE: 5-10 BA R. |--| A1D00116933
|
Siemens
|
|
A1D00116926
|
THIS SOFTWARE MUST BE INSTALLED ON THE SIPLACE STATION TO ENAB LE THE STATION TO COMMUNICATE W ITH THE SETUP CENTER BASIC PACK AGE. THIS IS REQUIRED FOR EACH C/S/F/HS/HF/XX/D-SERIES STATIO N THAT WILL BE CONNECT TO THE S ETUP CENTER BASIC PACKAGE. |--| A1D00116926
|
Siemens
|
|
A1D00119796
|
TO USE A VACUUM PUMP IN SIPLACE X-SERIES WITH THE 6/12 NOZZLE COLLECT & PLACE HEAD THIS RETRO FIT KIT IS NECESSARY. PER HEAD ONE RETROFIT KIT IS NECESSARY. IN ADDITION ONE MACHINE RETROF IT KIT IS REQUIRED. THE RETROFI T KITS ARE NECESSARY FOR NEW MA CHINE ORDER AS WELL AS FOR RETR OFIT IN FIELD. |--| A1D00119796
|
Siemens
|
|
A1D00119792
|
THE RETROFIT KIT IS NECESSARY T O USE A VACUUM PUMP WITH SIPLAC E X3 / D3. IN ADDITION ONE HEAD RECONFIGURATION KIT PER COLLEC T AND PLACE HEAD IS REQUIRED.TH E RETROFIT KITS ARE NECESSARY F OR NEW MACHINE ORDER AS WELL AS FOR RETROFIT IN FIELD. TO GUAR ANTEE THE SPECIFICATION OF THE SIPLACE MACHINE THE VACUUMPUMP MUST FULFILL THE SPECIFICATION OF SIEMENS. MORE DETAILS FROM T HE RESPECTIVE SALES OR SERVICE REPRESENTATIVE. THE VACUUM PUMP DONT WORK WITH SR SW 604 AND SR SW 605 IN COMBINATION WITH C P20. |--| A1D00119792
|
Siemens
|
|
A1D00116935
|
SIPLACE SPLICE DETECTION HUB FO R TABLE CONTROLLER: THIS ITEM I S NEEDED TO PREPARE A SIPLACE S TATION FOR SPLICE DETECTION. IT CONTAINS A HUB FOR CONNECTION OF UP TO 2 TABLE CONTROLLERS FO R SIPLACE S/F. ALSO, CABLING AN D MOUNTING MATERIAL IS INCLUDED . ADDITIONALLY, THE RESPECTIVE TABLE CONTROLLER(S) AND SPLICE SENSORS NEED TO BE ORDERED. |--| A1D00116935
|
Siemens
|
|
A1D00116936
|
SIPLACE SPLICE DETECTION HUB FO R TABLE CONTROLLER: THIS ITEM I S NEEDED TO PREPARE A SIPLACE S TATION FOR SPLICE DETECTION. IT CONTAINS A HUB FOR CONNECTION OF UP TO 4 TABLE CONTROLLERS FO R SIPLACE HS-XX. ALSO, CABLING AND MOUNTING MATERIAL IS INCLUD ED. ADDITIONALLY, THE RESPECTIV E TABLE CONTROLLER(S) AND SPLIC E SENSORS NEED TO BE ORDERED. |--| A1D00116936
|
Siemens
|
|
A1D00119793
|
THE RETROFIT KIT IS NECESSARY T O USE A VACUUM PUMP WITH SIPLAC E X2.IN ADDITION ONE HEAD RECON FIGURATION KIT PER COLLECT AND PLACE HEAD IS REQUIRED.THE RETR OFIT KITS ARE NECESSARY FOR NEW MACHINE ORDER AS WELL AS FOR R ETROFIT IN FIELD. TO GUARANTEE THE SPECIFICATION OF THE SIPLAC E MACHINE THE VACUUMPUMP MUST F ULFILL THE SPECIFICATION OF SIE MENS. MORE DETAILS FROM THE RES PECTIVE SALES OR SERVICE REPRES ENTATIVE. THE VACUUM PUMP DONT WORK WITH SR SW 604 AND SR SW 605 IN COMBINATION WITH CP20. |--| A1D00119793
|
Siemens
|
|
A1D00119795
|
THE VACUUM PUMP CAN BE CONNECTE D TO SIPLACE X4, SIPLACE X3 AND SIPLACE X2, IF THE PLACEMENT S TATIONS ARE EQUIPPED WITH THE O PTION RETROFIT VACUUM PUMP. VOL TAGE 110 V (3-208V). THIS PUMP IS ONLY REQUIRED WHEN 20 NOZZLE COLLECT & PLACE HEADS ARE USED . FOR ALL OTHER HEAD COMBINATIO NS ALSO THE PUMP UNDER ITEM NUM BER 119017 CAN BE USED. |--| A1D00119795
|
Siemens
|
|
A1D00116945
|
GRIP TO RETROFIT THE MC 70 PDA SCANNER. THIS GRIP IMPROVES THE ERGONOMIC HANDLING OF THE MC 7 0 PDA. |--| A1D00116945
|
Siemens
|
|
A1D00119800
|
SMD PLACEMENT STATION SIPLACE D 1 FOR END-OF-LINE/HIGH-END COMP ONENTS WITH A MAXIMUM PLACEMENT RATE OF 15,000 COMPONENTS PER HOUR. FOR DETAILS SEE CURRENT V ALID SCOPE OF SERVICE AND DELIV ERY. THE PLACEMENT STATION PROV IDES A COMPONENT FEEDING CAPACI TY OF MAXIMUM 90 X 8MM TAPES. T HE PLACEMENT STATION CAN BE CON FIGURED WITH ONE PICK AND PLACE HEAD AND ALTERNATIVE WITH A 12 -SEGMENT COLLECT AND PLACE HEAD OR A 6-SEGMENT COLLECT AND PLA CE HEAD WITH INTEGRATED COMPONE NT VISION. ADDITIONAL TO THAT, THE SIPLACE D1 CAN BE EQUIPPED ONLY WITH ONE PLACEMENT HEAD: D 1 (6), D1 (12), D1 (PP). DEPEND ING ON THE HEAD CONFIGURATION T |--| A1D00119800
|
Siemens
|
|
A1D00116936-01
|
SIPLACE SPLICE DETECTION HUB FO R TABLE CONTROLLER: THIS ITEM I S NEEDED TO PREPARE A SIPLACE S TATION FOR SPLICE DETECTION. IT CONTAINS A HUB FOR CONNECTION OF UP TO 4 TABLE CONTROLLERS FO R SIPLACE HS-XX. ALSO, CABLING AND MOUNTING MATERIAL IS INCLUD ED. ADDITIONALLY, THE RESPECTIV E TABLE CONTROLLER(S) AND SPLIC E SENSORS NEED TO BE ORDERED. |--| A1D00116936-01 |--| A1D0011693601
|
Siemens
|
|
A1D00119794
|
THE VACUUM PUMP CAN BE CONNECTE D TO SIPLACE X4, SIPLACE X3, SI PLACE X2 AND SIPLACE D3, IF THE PLACEMENT STATIONS ARE EQUIPPE D WITH THE OPTION RETROFIT VACU UM PUMP. VOLTAGE 50HZ 220V (3-4 00V). THIS PUMP IS ONLY REQUIRE D WHEN 20 NOZZLE COLLECT & PLAC E HEADS ARE USED. FOR ALL OTHER HEAD COMBINATIONS ALSO THE PUM P UNDER ITEM NUMBER 119017 CAN BE USED. NOT IN COMBINATION WIT H SR SW 604. |--| A1D00119794
|
Siemens
|
|
A1D00116941
|
THIS PACKAGE IS NECESSARY FOR T HE UPGRADE FROM SMV TO SIPLACE SETUP CENTER 2.1. THE CURRENT S OFTWARE VERSIONS 407.503 AND 50 5, THE COMPONENT LEVEL INDICATO R SOFTWARE, THE COMPONENT VERIF ICATION SOFTWARE AND THE TRACEA BILITY (XML-INTERFACE) ARE CONT ENTS OF THE PACKAGE. THIS ITEM IS REQUIRED ONE TIME PER FACTOR Y FOR SIPLACE S/F, HS-XX, HF OR HF/3. PLEASE NOTE: THE ITEMS F OR INSTALLATION OF SPLICE DETEC TION ARE NOT INCLUDED. |--| A1D00116941
|
Siemens
|
|
A1D00119811
|
THE FEEDER PROTECTION CONSISTS OF A COVER OVER THE FEED AREA. IF A FEEDER IS PRESSED UP OR IF FEEDER FLAPS ARE PROJECTING UP WARDS, THE EMERGENCY OFF IS ACT UATED. THE OPTION CONTAINS ONE PROTECTION PLATE FOR THE FEEDER AREA (LOCATION) 2 OF THE SIPLA CE D1. |--| A1D00119811
|
Siemens
|
|
A1D00116937
|
SIPLACE SPLICE DETECTION HUB FO R TABLE CONTROLLER: THIS ITEM I S NEEDED TO PREPARE A SIPLACE P LACEMENT STATION FOR SPLICE DET ECTION. IT CONTAINS A HUB FOR C ONNECTION OF UP TO 4 TABLE CONT ROLLERS FOR SIPLACE HF/HF3/D3. ALSO, CABLING AND MOUNTING MATE RIAL IS INCLUDED. ADDITIONALLY, THE RESPECTIVE TABLE CONTROLLE R(S) AND SPLICE SENSORS NEED TO BE ORDERED. MOMENT THE SPLICE DETECTION CO ULD NOT BE USED ON THE SIPLACE D3, ONLY ON THE SIPLACE HF/HF3 WITH THE SOFTWARE 50X. |--| A1D00116937
|
Siemens
|
|
A1D00119818
|
THE COMP-CAMERA STAT. P+P (TYPE 33) 55X45 D1 IS AN ALTERNATIVE CAMERA TO THE STANDARD CAMERA (TYPE 36) OF THE PICK & PLACE H EAD AT THE SIPLACE D1.EXCHANGE BETWEEN THE STANDARD CAMERA (TY PE 36) AT THE MANUFACTURING OF THE MACHINE. THE STANDARD COMPO NENT CAMERA IS THEN NOT PART OF DELIVERY. THE COMP-CAMERA STAT . P+P (TYPE 33) 55X45 D1 OFFERS A HIGHER RESOLUTION (41UM) AND A LARGER USEABLE COMPONENT RAN GE UP TO 55 X 45MM. THE STATION ARY CAMERA COULD BE ORDERED FOR EXAMPLE IF THE RESOLUTION OF T HE STANDARD CAMERA IS NOT SUFFI CIENT OR MORE COMPONENTS LARGER THEN 32 X 32MM WILL BE PLACED. THE COMPONENT RANGE AT SINGLE |--| A1D00119818
|
Siemens
|
|
A1D00116939
|
THIS SOFTWARE IS NEEDED ADDITIO NAL TO THE SIPLACE SETUP CENTER STATION SOFTWARE FOR EVERY STA TION. THIS SOFTWARE IS A DATA I NTERFACE FOR TRACEABILITY. |--| A1D00116939
|
Siemens
|
|
A1D00116943
|
THIS PACKAGE IS NECESSARY FOR T HE UPGRADE FROM SMV TO SIPLACE SETUP CENTER 2.3. THE CURRENT S OFTWARE VERSIONS 407.503 AND 50 5, THE COMPONENT LEVEL INDICATO R SOFTWARE, THE COMPONENT VERIF ICATION SOFTWARE AND THE TRACEA BILITY (XML-INTERFACE) ARE CONT ENTS OF THE PACKAGE. THIS ITEM IS REQUIRED ONE TIME PER FACTOR Y FOR SIPLACE S/F, HS-XX, HF OR HF/3. PLEASE NOTE: THE ITEMS F OR INSTALLATION OF SPLICE DETEC TION ARE NOT INCLUDED. |--| A1D00116943
|
Siemens
|
|
A1D00119819
|
MEASUREMENT DEVICE FOR INSPECTI ON OF THE CO-PLANARITY FOR LEAD ED COMPONENTS, WHEN HAVING GULL WINGS. FOR USE WITH THE PICK & PLACE MODULE OF THE D1. |--| A1D00119819
|
Siemens
|
|
A1D00119812
|
THE FEEDER PROTECTION CONSISTS OF A COVER OVER THE FEED AREA. IF A FEEDER IS PRESSED UP OR IF FEEDER FLAPS ARE PROJECTING UP WARDS, THE EMERGENCY OFF IS ACT UATED. THE OPTION CONTAINS ONE PROTECTION PLATE FOR THE FEEDER AREA (LOCATION) 1 OF THE SIPLA CE D1. |--| A1D00119812
|
Siemens
|
|
A1D00116944
|
THIS 1D/2D PDA-SCANNER IS NEEDE D FOR THE COMPONENT SETUP VERIF ICATION, AT LEAST ONE TIME PER LINE. THE SCANNER COMMUNICATES VIA LAN ACCESSPOINT WITH THE CO MPONENT SETUP VERIFICATION SYST EM. NOTE: THIS SCANNER CAN ONLY BE USED IN COMBINATION WITH A LAN ACCESSPOINT. |--| A1D00116944
|
Siemens
|