HHED

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
HHED62B020L THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62M060 THERMAL MAGNETIC; 2 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B015 THERMAL MAGNETIC; 3 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M020 THERMAL MAGNETIC; 3 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63B070L THERMAL MAGNETIC; 3 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B040 THERMAL MAGNETIC; 2 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B035L THERMAL MAGNETIC; 3 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63M025 THERMAL MAGNETIC; 3 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62B035 THERMAL MAGNETIC; 2 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B070L THERMAL MAGNETIC; 2 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62M045 THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B125 THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HHED62M025 THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62B025L THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B100 THERMAL MAGNETIC; 2 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B080 THERMAL MAGNETIC; 3 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B080 THERMAL MAGNETIC; 3 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B110L THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63B015L THERMAL MAGNETIC; 3 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B035L THERMAL MAGNETIC; 2 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62B080L THERMAL MAGNETIC; 2 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63B090 THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M110 THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _ Siemens
HHED62B045 THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
ED21B020 600 - 600 VAC; 40 - 40 A; INTERRUPT RATING 25000 AMPERE; 3 POLE; WIDTH 3 INCH; DEPTH 4.56 INCH; HEIGHT 6.53 INCH; TRIPPING METHOD MAGNETIC, THERMAL; NEMA 1, 3R, 5, 7, 9, 12, 12K _ Siemens
HHED63M070 THERMAL MAGNETIC; 3 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B060L THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M100 THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B045L THERMAL MAGNETIC; 3 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B015L THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B110L THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B025L THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B125L THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63B015L THERMAL MAGNETIC; 3 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B125L THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B020L THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63B040 THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B080L THERMAL MAGNETIC; 2 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63M125 CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62B020 THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63B025 THERMAL MAGNETIC; 3 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M040 THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B090L THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B045L THERMAL MAGNETIC; 3 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M025 THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63B050LAC 50A 3P 600V CB _ Siemens
HHED63B040L THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B090L THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B050 THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B050L THERMAL MAGNETIC; 2 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63B080L THERMAL MAGNETIC; 3 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B070 THERMAL MAGNETIC; 3 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M030 THERMAL MAGNETIC; 3 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B100L THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B020LSN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62M015 THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62B045 THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B015L THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63M060 THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B030L THERMAL MAGNETIC; 3 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62B090L THERMAL MAGNETIC; 2 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63B025L THERMAL MAGNETIC; 3 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M080 THERMAL MAGNETIC; 3 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B125 THERMAL MAGNETIC; 3 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HHED63M040LSN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63M080L CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62M030 THERMAL MAGNETIC; 2 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M050 THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B060L THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M080L CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63B040SN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG); 10 TO 1/0 AWG ALUMINUM/COPPER (ALUMINUM LUG) _ Siemens
HHED63B060 THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M050 THERMAL MAGNETIC; 2 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B100L THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B045L THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63B110L THERMAL MAGNETIC; 3 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HHED62B020 THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M060 THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M090 THERMAL MAGNETIC; 2 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B040 THERMAL MAGNETIC; 2 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M080 THERMAL MAGNETIC; 2 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M035 THERMAL MAGNETIC; 3 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M050 THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B080 THERMAL MAGNETIC; 2 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
ED21B015 600 - 600 VAC; 30 - 30 A; INTERRUPT RATING 25000 AMPERE; 3 POLE; WIDTH 3 INCH; DEPTH 4.56 INCH; HEIGHT 6.53 INCH; TRIPPING METHOD MAGNETIC, THERMAL; NEMA 1, 3R, 5, 7, 9, 12, 12K _ Siemens
HHED62B060 THERMAL MAGNETIC; 2 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B090 THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B110L THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63B125L THERMAL MAGNETIC; 3 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HHED62B025 THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62M100 THERMAL MAGNETIC; 2 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B100 THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B030SN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG); 10 TO 1/0 AWG ALUMINUM/COPPER (ALUMINUM LUG) _ Siemens
HHED63B050L THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M100L CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B025L THERMAL MAGNETIC; 2 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63S100A MOLDED CASE SWITCH, MOLDED CASE, THERMAL MAGNETIC; ED FRAME; 600 VAC; 100 AMPERE; 3 POLE; AUTOMATICALLY SELF PROTECTED WITH SWITCH _ Siemens
HHED63B070LAEAE CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63M040 THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B015 THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M090 THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B070 THERMAL MAGNETIC; 2 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M110 110A 3P 600V CB _ Siemens
HHED63B070LSN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62B040L THERMAL MAGNETIC; 2 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62M070 THERMAL MAGNETIC; 2 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M030L 600 - 600 VAC; 30 - 30 A; INTERRUPT RATING 25000 AMPERE; 3 POLE; WIDTH 3 INCH; DEPTH 4.56 INCH; HEIGHT 6.53 INCH; TRIPPING METHOD MAGNETIC, THERMAL; NEMA 1, 3R, 5, 7, 9, 12, 12K _ Siemens
HHED62M015 THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M060L CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63B100 THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M040 THERMAL MAGNETIC; 2 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M015 THERMAL MAGNETIC; 3 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62B125L THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63M020L CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62M050 THERMAL MAGNETIC; 2 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M100 THERMAL MAGNETIC; 2 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63S100A MOLDED CASE SWITCH, MOLDED CASE, THERMAL MAGNETIC; ED FRAME; 600 VAC; 100 AMPERE; 3 POLE; AUTOMATICALLY SELF PROTECTED WITH SWITCH _ Siemens
HHED62B125 THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HED43M100LBESN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62B060 THERMAL MAGNETIC; 2 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M080 THERMAL MAGNETIC; 3 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B125LAE CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63M100 THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B040 THERMAL MAGNETIC; 3 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B045 THERMAL MAGNETIC; 3 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B125LAC CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62M125 THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _ Siemens
HHED63B070L THERMAL MAGNETIC; 3 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M070 THERMAL MAGNETIC; 2 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B045L THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62M045 THERMAL MAGNETIC; 2 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B060 THERMAL MAGNETIC; 3 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B015 THERMAL MAGNETIC; 2 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63B020 THERMAL MAGNETIC; 3 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62B030 THERMAL MAGNETIC; 2 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B030 THERMAL MAGNETIC; 3 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M090 THERMAL MAGNETIC; 2 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B030 THERMAL MAGNETIC; 2 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B070L THERMAL MAGNETIC; 2 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63B050 THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M045 THERMAL MAGNETIC; 3 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HED43M100LBESN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63B015L THERMAL MAGNETIC; 3 POLE; 600 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED62B030L THERMAL MAGNETIC; 2 POLE; 600 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62M110 THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _ Siemens
HHED63M125 CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62B110 THERMAL MAGNETIC; 2 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HHED63B090LAE CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62B035 THERMAL MAGNETIC; 2 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M025 THERMAL MAGNETIC; 3 POLE; 600 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63M020 THERMAL MAGNETIC; 3 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED62B125L THERMAL MAGNETIC; 2 POLE; 600 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63M020LSN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED63M045 THERMAL MAGNETIC; 3 POLE; 600 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B035 THERMAL MAGNETIC; 3 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B035 THERMAL MAGNETIC; 3 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B110 THERMAL MAGNETIC; 3 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER _ Siemens
HHED63B050L THERMAL MAGNETIC; 3 POLE; 600 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B040SN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG); 10 TO 1/0 AWG ALUMINUM/COPPER (ALUMINUM LUG) _ Siemens
HHED62M080 THERMAL MAGNETIC; 2 POLE; 600 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B100L THERMAL MAGNETIC; 2 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62B035L THERMAL MAGNETIC; 2 POLE; 600 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED62B090 THERMAL MAGNETIC; 2 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B030SN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG); 10 TO 1/0 AWG ALUMINUM/COPPER (ALUMINUM LUG) _ Siemens
HHED63M090 THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63B070 THERMAL MAGNETIC; 3 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED63M100L CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 600 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M060 THERMAL MAGNETIC; 2 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B070 THERMAL MAGNETIC; 2 POLE; 600 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62M040 THERMAL MAGNETIC; 2 POLE; 600 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
HHED62B020L THERMAL MAGNETIC; 2 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER, LINE/LOAD) _ Siemens
HHED63B060LSN CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens
HHED62B060L THERMAL MAGNETIC; 2 POLE; 600 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LOAD) _ Siemens
HHED63B020 THERMAL MAGNETIC; 3 POLE; 600 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 65 KILOAMPERE AT 480 VAC, 25 KILOAMPERE AT 600 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _ Siemens
HHED63B040LAESD CIRCUIT BREAKER, THERMAL MAGNETIC; 3 POLE; 480 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG) _ Siemens