HED4
Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
HED43B125L
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC (UL); LUG TERMINAL; WIRE SIZE 1 TO 2/0 AWG ALUMINUM, (3) 3 TO 3/0 AWG COPPER; SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED41B060
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 25 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 4 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED41M070
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 25 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED42B080
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED43B070SN
|
70A 3P 480VAC CB _
|
Siemens
|
HED43B020
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _
|
Siemens
|
HED42M100
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED41B020L
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 65 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG TERMINAL; SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H; APPROVAL UL 489, CSA 22.2 _
|
Siemens
|
HED41B015L
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 65 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG TERMINAL; SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H; APPROVAL UL 489, CSA 22.2 _
|
Siemens
|
HED41B020L
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 65 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG TERMINAL; SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H; APPROVAL UL 489, CSA 22.2 _
|
Siemens
|
HED41B025L
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 65 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG TERMINAL; SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H; APPROVAL UL 489, CSA 22.2 _
|
Siemens
|
HED42M125
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _
|
Siemens
|
HED42M125
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _
|
Siemens
|
HED43B090L
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC (UL); LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER); SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED43B030
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER); SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED42B110
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL _
|
Siemens
|
HED41M050
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 25 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED42B020
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL _
|
Siemens
|
HED41B100L
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 25 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG TERMINAL; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED43M110
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _
|
Siemens
|
HED41B025
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 65 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG LOAD TERMINAL TERMINAL; SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED43M030
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER); SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED41B020L
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 65 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG TERMINAL; SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H; APPROVAL UL 489, CSA 22.2 _
|
Siemens
|
HED43M060
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER); SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED42M090
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED41B040
|
THERMAL MAGNETIC; 1 POLE; 277 VAC, 125 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 120 VAC, 25 KILOAMPERE AT 277 VAC, 30 KILOAMPERE AT 125 VDC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 4 AWG (ALUMINUM/COPPER) _
|
Siemens
|
HED43M125
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 1 TO 2/0 AWG (ALUMINUM), 3 TO 3/0 AWG (COPPER) _
|
Siemens
|
HED43B080
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER); SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H _
|
Siemens
|
HED42B125
|
THERMAL MAGNETIC; 2 POLE; 480 VAC, 250 VDC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL _
|
Siemens
|
HED43B020
|
THERMAL MAGNETIC; 3 POLE; 480 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 100 KILOAMPERE AT 240 VAC, 42 KILOAMPERE AT 480 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM), 14 TO 10 AWG (COPPER) _
|
Siemens
|
Òîâàðû
31 - 60 èç 203
Íà÷àëî
|
Ïðåä.
|
1
2
3
4
5
|
Ñëåä. |
Êîíåö