BQ3B

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
BQ3B04000S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B045 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 45 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _ Siemens
BQ3B060 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _ Siemens
BQ3B04500S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 45 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B035Y 3P 35A 240V CB _ Siemens
BQ3B07000S07 CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _ Siemens
BQ3B05000S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B02000S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B070C CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _ Siemens
BQ3B060HQ CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22000 AMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _ Siemens
BQ3B070H MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _ Siemens
BQ3B080 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _ Siemens
BQ3B080H MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _ Siemens
BQ3B050HL MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQH FRAME; 240 VAC AT 60 HZ; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120/240 VAC; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 2.37 INCH D X 3.75 INCH H _ Siemens
BQ3B035C CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _ Siemens
BQ3B030C CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _ Siemens
BQ3B020H MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _ Siemens
BQ3B08000S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B015 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _ Siemens
BQ3B070Y MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 5 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL; BQ MODEL; CALIBRATION AT 400 HZ _ Siemens
BQ3B09000S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B080 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _ Siemens
BQ3B040 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _ Siemens
BQ3B020QL CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _ Siemens
BQ3B01500S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B050 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _ Siemens
BQ3B030HL MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _ Siemens
BQ3B02000S01 MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _ Siemens
BQ3B050LA01 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 2.37 INCH D X 3.75 INCH H; SPEEDFAX[T] BRAND; BQ MODEL _ Siemens
BQ3B050A01 MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 2.37 INCH D X 3.75 INCH H; SPEEDFAX[T] BRAND; BQ MODEL _ Siemens

Òîâàðû 61 - 90 èç 176