| product name | closed-loop control infeed/regenerative feedback module |
| Unit type | infeed module |
| Function status | 1 |
| Cooling | hose |
| cooling method | separate cooling |
| degree of protection | IP 20 for the electronics area and IP 54 for the heatsink in the heat dissipation area |
| weight / approx. | 26 kg |
| dimension / width | 300 mm |
| dimension / height | 480 mm |
| dimension / depth | 288 mm |
| infeed / type | closed-loop |
| connection / power connection | 95 mm2 or 2 x 35 mm2 |
| Connection / line connection / cross-section / max. | 95 mm² |
| | |
|
| rated output / infeed | 55 kW |
| rated output / infeed / S3-60 % | 71 kW |
| rated output / infeed / peak power | 91 kW |
| rated output / regenerative feedback | 55 kW |
| rated output / regenerative feedback / peak power | 91 kW |
| rated current In | 92.5 A |
| rated current In / Input / at undervoltage | 103 A |
| Rated current In / Output / Peak current | 153 A |
| Input voltage | 400 V 3-phase AC -10% to 480 V 3-phase AC + 6 % |
| Output voltage | 600V / 625V / 680V |
| power frequency / min. | 50 Hz |
| power frequency / tolerance / min. | -10 % |
| power frequency / max | 60 Hz |
| power frequency / tolerance / max | 10 % |
| Efficiency eta | 0.977 |
| charging limit | 20000 µF |
| power factor / cos phi / sine current mode | 0.98 |
| power factor / cos phi / block current mode | 0.98 |
| power factor / cos lambda / sine current mode | 0.97 |
| power factor / cos lambda / block current mode | 0.89 |
| impedance voltage / required / maximum | 3 % |
| | |
|
| ambient temperature on operation / min. | 0 °C |
| ambient temperature / during operation / max. | 40 °C |
| ambient temperature / during operation / max. / with power reduction | 55 °C |
| ambient temperature / when stored / min. | -40 °C |
| ambient temperature / when stored / max. | 70 °C |
| ambient temperature / when transported / min. | -40 °C |
| ambient temperature / when transported / max. | 70 °C |
| | |