RSD-FC-Ex2.CN.3km - ControlNet LWL adapter | RSD-FC-Ex2.CN.3km - Quad Industry GmbH
Артикул: RSD-FC-Ex2.CN.3km
Наименование: ControlNet LWL adapter | RSD-FC-Ex2.CN.3km
Производитель: Pepperl-Fuchs
|
|
- Converts the TTL signals of the ControlNet copper/fiber optic adapter into LWL signals
- LWL channels: EEx ia IIC
- Device installation in Zone 1, Zone 2, or Zone 22
- Transfer range up to 3 km
- Transfer rate 5 MBits/s
- Two bi-directional fiber optic connections
- Power supply channel via the copper/fiber optic adapter
Datasheet as PDF in following languages: Technical Data: RSD-FC-Ex2.CN.3km| Supply | | Connection | 30-pin bus connector | | Internal bus | | Connection | TTL bus | | Interface | manufacturer specific bus | | External bus | | Connection | fiber optic cable | | Interface | ControlNet international version 1.5, intrinsically safe | | Transfer rate | 5 MBit/s | | Fiber optic type | 62.5/125 micron | | Fiber optic connection | ST (ceramic) | | Fiber optic wave length | 1300 nm | | Directive conformity | | Electromagnetic compatibility | | | Directive 2004/108/EC | EN 61326-1:2006 | | Explosion protection | | | Directive 94/9/EC | EN 60079-0: 2006, EN 60079-11: 2007 , EN 60079-26:2007 | | Standard conformity | | Insulation coordination | EN 50178 | | Electrical isolation | EN 60079-11:2007 | | Electromagnetic compatibility | NE 21:2006 | | Protection degree | IEC 60529 | | Climatic conditions | DIN IEC 721 | | Ambient conditions | | Classification | 3K3 | | Ambient temperature | -20 ... 70 В°C (-4 ... 158 В°F) | | Storage temperature | -20 ... 100 В°C (-4 ... 212 В°F) | | Relative humidity | 95 % non-condensing | | Shock resistance | 15 g peak, 11 ms period | | Vibration resistance | 2 g , 10 ... 500 Hz according to IEC 60068-2-6 | | Damaging gas | acc. to ISA-S71.04-1985, severity level G3 | | Mechanical specifications | | Connection type | fiber optic cable | | Protection degree | IP20, for on-site installation a separate housing is required with a minimum of IP54 | | Mass | approx. 140 g | | Mounting | DIN rail mounting | | Data for application in connection with Ex-areas | | EC-Type Examination Certificate | DMT 99 ATEX 010 X , for additional certificates see www.pepperl-fuchs.com | | Group, category, type of protection | II (1)2G EEx ia/ib IIB/IIC | | Temperature class | T4 | | Supply | only in connection with RSD-CFA-Ex.CN | | Internal bus | customer specific | | Statement of conformity | | | Group, category, type of protection, temperature class | II 3D IP54 T 90В°C | | Electrical isolation | | | Internal/external bus | safe galvanic isolation acc. to EN 60079-11:2007 | | Internal bus/power supply | no electrical isolation | | External bus/power supply | safe galvanic isolation acc. to EN 60079-11:2007 |
|
Назад в раздел
|