Производитель: Pepperl-Fuchs
|
|
- Sensing range up to 15 m
- Resolution 30 mm (hand protection)
- Protection field height up to 1650 mm
- Self-monitoring (type 4 according to IEC/EN 61496-1)
- Master/Slave detection, Plug and Play
- Start/Restart disable
- Protection degree IP67
- Integrated function display
- Pre-fault indication
- Safety outputs OSSD in potential-separated semiconductor design or with monitored, compelled connection NC-contacts
- Optional with ATEX certificates for zone 2 and 22 and protection degree IP66 (Option 133)
Datasheet as PDF in following languages: Technical Data: SLC30-300-S| General specifications | | Effective detection range | 0.2 ... 15 m | | Light source | IRED | | Light type | modulated infrared light | | Safety type according to IEC/EN 61496 | 4 | | Marking | CE | | Protection field height | 300 mm | | Number of beams | 16 | | Operating mode | in the master | | Optical resolution | 30 mm | | Angle of divergence | < 5 В° | | Functional safety related parameters | | Safety Integrity Level (SIL) | SIL 3 | | Performance level (PL) | PL e | | Category | Cat. 4 | | Mission Time (TM) | 20 a | | PFHd | 1.35 E-8 | | Indicators/operating means | | Diagnostics display | in the master | | Function display | in the master | | Pre-fault indication | in the master | | Electrical specifications | | Operating voltage | from master | | Input | | Function input | in the master | | Output | | Safety output | in the master | | Signal output | in the master | | Mechanical specifications | | Protection degree | IP67 | | Connection | M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 |
|
Назад в раздел
|