| Product Description |
G2 safety module 2 safety-related inputs |
| General specifications |
| Slave type | Safety-Slave |
| AS-Interface specification | V2.1 |
| Required master specification | ≥ V2.0 |
| UL File Number | E87056 |
| Functional safety related parameters |
| Safety Integrity Level (SIL) | SIL 3 |
| MTTFd | 200 a |
| Indicators/operating means |
| LED FAULT | error display; LED red red: communication error or address is 0 |
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 2 LED yellow |
| Electrical specifications |
| Rated operating voltage | 26.5 ... 31.6 V PELV from AS-Interface |
| Rated operating current | ≤ 70 mA |
| Protection class | III |
| Input |
| Number/Type | 2 safety-related inputs for mechanical contacts, cross-circuit monitored: 2 single-channel contacts: up to category 2 in accordance with EN 954-1 or 1, 2-channel contact: up to category 4 in accordance with EN 954-1 Cable length must not exceed 30 m per input. |
| Supply | from AS-Interface |
| Voltage | 20 ... 30 V DC pulsed |
| Current loading capacity | input current limited ≤ 15 mA, overload and short-circuit resistant |
| Programming instructions |
| Profile | S-0.B |
| IO code | 0 |
| ID code | B |
| ID1 code | F |
| ID2 code | 0 |
| Data bits (function via AS-Interface) | input output |
| D0 | dyn. safety code 1 - |
| D1 | dyn. safety code 1 - |
| D2 | dyn. safety code 2 - |
| D3 | dyn. safety code 2 - |
| Parameter bits (programmable via AS-i) | function |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
| Compliance with standards and directives |
| Directive conformity | |
| EMC Directive 2004/108/EC | EN 61326, EN 50295, EN 61496-1 |
| Standard conformity | |
| Electromagnetic compatibility | EN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4 |
| Emitted interference | EN 61000-6-4:2001 |
| Insulation coordination | EN 50178:1998 |
| Functional safety | EN 954-1:1996 (up to category 4), BIA Final Draft "Proposal for a principle to the verification and certification of field busses for transmission of safety related signals" 28.05.2000, IEC 61508 up to SIL3 |
| Protection degree | EN 60529:2000 |
| Fieldbus standard | EN 50295:1999, IEC 62026-2:2006 |
| Electrical safety | EN 60947-5-1:2005 , IEC 60204-1:2007 |
| Ambient conditions |
| Ambient temperature | -25 ... 55 В°C (-13 ... 131 В°F) |
| Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
| Mechanical specifications |
| Protection degree | IP67 |
| Connection | Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector |
| Material | |
| Housing | PBT |
| Mass | 100 g |
| Mounting | Mounting base |