| Product Description |
G4 PG module IP67 safety module with 2 inputs |
| General specifications |
| Slave type | Safety-Slave |
| AS-Interface specification | V2.1 |
| Required master specification | ≥ V2.0 |
| UL File Number | E87056 |
| Indicators/operating means |
| LED FAULT | error display; LED red red: communication error or address is 0 |
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 2 LED yellow |
| Electrical specifications |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | ≤ 70 mA |
| Protection class | III |
| Fault current | max. 90 mA |
| Input |
| Number/Type | 2 Inputs for SN sensors (category S, EN 60947-5-3; category 3+4, EN 954-1) or for mechanical contacts (category 4, EN 954-1) Inputs for mech. switch, monitored for cross-circuit, cable length < 30 m |
| Supply | from AS-Interface |
| Current loading capacity | input current limited ≤ 15 mA, overload and short-circuit resistant |
| Switching point | SN specification mech. switch current 10 mA pulsed |
| Programming instructions |
| Profile | S-0.B |
| IO code | 0 |
| ID code | B |
| ID1 code | F |
| ID2 code | E |
| Data bits (function via AS-Interface) | input output |
| D0 | dyn. safety code 1 - |
| D1 | dyn. safety code 1 - |
| D2 | dyn. safety code 2 - |
| D3 | dyn. safety code 2 - |
| Parameter bits (programmable via AS-i) | function |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
| Compliance with standards and directives |
| Directive conformity | |
| EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 61000-6-4:2007, EN 50295:1999 |
| Standard conformity | |
| Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-4-x, EN 61000-4-5:2005 1kV asymmetric, criterion B, EN 61000-6-4:2007, EN 55011:2009 |
| Emitted interference | EN 61000-6-4:2001 |
| Insulation coordination | EN 50178:1998 |
| Functional safety | DIN EN 954-1:1996 (by category 4) , IEC 60947-5-3:1999 |
| Protection degree | EN 60529:2000 |
| Fieldbus standard | EN 50295:1999, IEC 62026-2:2006 |
| Electrical safety | IEC 60204-1:2007 |
| Ambient conditions |
| Ambient temperature | -25 ... 55 В°C (-13 ... 131 В°F) |
| Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
| Relative humidity | < 95 % |
| Mechanical specifications |
| Protection degree | IP67 |
| Connection | cable piercing method or terminal compartment yellow flat cable or standard round cable inputs: M12 x 1.5 cable gland and cage tension spring terminals |
| Material | |
| Housing | PA 6 GF30 |
| Mass | 180 g |
| Mounting | DIN rail or screw mounting |