Àðòèêóë: 50120772
Íàèìåíîâàíèå: BCL 358i SF 100 - Stationary barcode reader
Ïðîèçâîäèòåëü: Leuze electronic
|
|
Part description | BCL 358i SF 100 - Stationary barcode reader | Part no. | 50120772 | -
Basic data -
Read data - Code types, readableGS1 Databar Expanded, EAN 8/13, Code 93, Code 39, Code 128, GS1 Databar Limited, GS1 Databar Omnidirectional, UPC, Codabar, 2/5 Interleaved
- Scanning rate, typical1.000 scans/s
-
Optics - Reading distance70 ... 445 mm
- Light sourcelaser, Red
- Laser light wavelength655 nm
- Laser safety class2, EN 60825
- Reading methodLine scanner with deflection mirror
- Beam deflectionBy means of rotating polygon mirror wheel + deflection mirror
- Light beam exitLateral with deflection mirror
-
Electrical equipment -
Performance data - Supply voltage18 ... 30 V, DC
- Power consumption, max.8 V·A
-
Inputs / outputs - Number of inputs/outputs selectable2 Piece(s)
-
Interface - TypeEtherNet IP
-
EtherNet IP - Switch functionalityintegrated
-
Service interface - TypeUSB
-
USB - FunctionConfiguration via software
-
Connection - Number of connections1 Piece(s)
-
Connection 1 - Type of connectionPlug connector
- FunctionService interface, Data interface, Connection to device, BUS IN, PWR / SW IN/OUT
- No. of pins32 Piece(s)
- ModelMale
-
Mechanical data - DesignCube
- Dimension103 mm x 44 mm x 96 mm
- Housing materialMetal, Diecast aluminum
- Lens cover materialGlass
- Net weight350 g
- Housing colorBlack, Red
- Type of fasteningFastening on back, Dovetail grooves
-
Operation and display - Type of displayLED
- Number of LEDs2 Piece(s)
- Type of configurationVia web browser
-
Environmental data - Ambient temperature, operation0 ... 40 °C
- Ambient temperature, storage-20 ... 70 °C
- Relative humidity (non-condensing)0 ... 90 %
-
Certifications - Protection classIP 65
- Safety classIII
- CertificationsCDRH, c UL US, CE
- Test procedure for EMC in accordance with standardEN 55022, EN 61000-4-2, 3, -4, -6
- Test procedure for shock in accordance with standardIEC 60068-2-27, test Ea
- Test procedure for continuous shock in accordance with standardIEC 60068-2-29, test Eb
- Test procedure for vibration in accordance with standardIEC 60068-2-6, test FC
-
Functions - FunctionsCode fragment technology, LED indicators, Reference code comparison, AutoControl, Alignment mode, AutoReflAct
-
3D-CAD models (1) -
Certificates (3) Part data of: 2013-11-24 21:03:00
|