TRA236

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
TRA236WW A range breakproof Room thermostat (make/break contact) Thermoplastic (breakproof) high-gloss Screwless terminals for wires up to 2.5 mm2 screw fixing only, without claws 1-pole, 2-way, heating 10 (4) A, AC 230 V ~, 50/60 Hz 1-pole, 2-way, cooling 5 (2) A, AC 230 V ~, 50/60 Hz For switching between heating/cooling the EBERLE terminal strip EV..H/K is necessary. (The value in brackets indicates inductive loads with cos ? = 0.6) Neutral conductor required. Hysteresis: 0.5 K Nominal range: +5 °C ... +30 °C When set temperature is reached the make/break contact switches over. JUNG
TRA236SW A range breakproof Room thermostat (make/break contact) Thermoplastic (breakproof) high-gloss Screwless terminals for wires up to 2.5 mm2 screw fixing only, without claws 1-pole, 2-way, heating 10 (4) A, AC 230 V ~, 50/60 Hz 1-pole, 2-way, cooling 5 (2) A, AC 230 V ~, 50/60 Hz For switching between heating/cooling the EBERLE terminal strip EV..H/K is necessary. (The value in brackets indicates inductive loads with cos ? = 0.6) Neutral conductor required. Hysteresis: 0.5 K Nominal range: +5 °C ... +30 °C When set temperature is reached the make/break contact switches over. JUNG
TRA236MO A range breakproof Room thermostat (make/break contact) Thermoplastic (breakproof) lacquered Screwless terminals for wires up to 2.5 mm2 screw fixing only, without claws 1-pole, 2-way, heating 10 (4) A, AC 230 V ~, 50/60 Hz 1-pole, 2-way, cooling 5 (2) A, AC 230 V ~, 50/60 Hz For switching between heating/cooling the EBERLE terminal strip EV..H/K is necessary. (The value in brackets indicates inductive loads with cos ? = 0.6) Neutral conductor required. Hysteresis: 0.5 K Nominal range: +5 °C ... +30 °C When set temperature is reached the make/break contact switches over. JUNG
TRA236CH A range breakproof Room thermostat (make/break contact) Thermoplastic (breakproof) lacquered Screwless terminals for wires up to 2.5 mm2 screw fixing only, without claws 1-pole, 2-way, heating 10 (4) A, AC 230 V ~, 50/60 Hz 1-pole, 2-way, cooling 5 (2) A, AC 230 V ~, 50/60 Hz For switching between heating/cooling the EBERLE terminal strip EV..H/K is necessary. (The value in brackets indicates inductive loads with cos ? = 0.6) Neutral conductor required. Hysteresis: 0.5 K Nominal range: +5 °C ... +30 °C When set temperature is reached the make/break contact switches over. JUNG
TRA236AL A range breakproof Room thermostat (make/break contact) Thermoplastic (breakproof) lacquered Screwless terminals for wires up to 2.5 mm2 screw fixing only, without claws 1-pole, 2-way, heating 10 (4) A, AC 230 V ~, 50/60 Hz 1-pole, 2-way, cooling 5 (2) A, AC 230 V ~, 50/60 Hz For switching between heating/cooling the EBERLE terminal strip EV..H/K is necessary. (The value in brackets indicates inductive loads with cos ? = 0.6) Neutral conductor required. Hysteresis: 0.5 K Nominal range: +5 °C ... +30 °C When set temperature is reached the make/break contact switches over. JUNG
TRA236 A range breakproof Room thermostat (make/break contact) Thermoplastic (breakproof) high-gloss Screwless terminals for wires up to 2.5 mm2 screw fixing only, without claws 1-pole, 2-way, heating 10 (4) A, AC 230 V ~, 50/60 Hz 1-pole, 2-way, cooling 5 (2) A, AC 230 V ~, 50/60 Hz For switching between heating/cooling the EBERLE terminal strip EV..H/K is necessary. (The value in brackets indicates inductive loads with cos ? = 0.6) Neutral conductor required. Hysteresis: 0.5 K Nominal range: +5 °C ... +30 °C When set temperature is reached the make/break contact switches over. JUNG