Product Specifications
- Application
- Electric Radiant Floor
- Dimensions (in.)
- 3.1 in. X 3.1 in. X 0.6 in.
- Dimensions (mm)
- 78.9 mm X 78.9 mm X 16.3 mm
- Includes
- 10-ft European sensor, Thermostat wall plate, Snubber assembly
- Used With
- Aube AC130-01 European floor sensor
- Comments
- On/Off Switch, Min. and max. temperature limits, Terminal for pilot wire programmer, Optional snubber connection for loads beyond 2000 W
- Mounting
- Vertical
- Electrical Ratings
- 3450 W (NI) @ 15 A max. (resistive only), 230 VAC
- Frequency
- 50 Hz
- Customer Special
- Etherma
- Electrical Connections
- Terminal block
- Supply Voltage
- 230 Vac
- Switch Positions (System)
- AF (ambient + floor)/F (floor only), On/Standby
- Sensor Element
- Thermistor
- Accuracy (C)
- ? 0.5 C
- Color
- White
- Switch Type
- Relay
- LEDs
- Pilot wire indicator, Heating indicator
- Power Method
- Hardwired
- Terminal Designations
- Power: 1 and 5, Load: 2 and 4, Pilot Wire: 3, Floor sensor:6 and 7
- Operation
- AF/F configuration switch must be set to AF for this thermostat to be operational.
- Changeover
- Automatic - receives orders from the Energy Management Program (pilot wire)
- Setting Temperature Range (C)
- 7 C (frost protection), 15 C to 35 C
- Cycles per Hour
- 4 CPH
- Heat Current
- 15 A (resistive only)
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.