| | Similar to image | | TEMPER. CONTROLLER FOR 230 V AC SETTING RANGE +40/+100 C CONTACT 230 V AC 16 A WITH TEMPERATURE SENSOR KTY |
| |
| Technical data: | | |
| Design type | | 7LQ2 0 temperature controllers |
| Type, explanations | | temperature controllers |
| Type, explanations / additionally | | With KTY 11-6 temperature sensor, Setting range +40 till +100 °C, 1 CO |
| Design of the switching function | | CO contact |
| Number of channels | | 1 |
| Number of basic programs / when delivered | | 0 |
| Number of pitch units for width | | 2 |
| Mounting depth | mm | 70 |
| Supply voltage / rated value | | |
| | V | 230 |
| | V | 230 |
| Supply voltage frequency / rated value | | |
| | Hz | 45 |
| | Hz | 65 |
| Protection class IP | | IP20 |
| Pouvoir de coupure courant | | |
- floating / at 250 V / nominal value
| A | 16 |
- avec potentiel / a 230 V / valeur nominale
| A | 16 |
| Sensor type | | remote sensor |
| Manner of function / of the temperature controller | | digital |
| Product component / mode selector switch | | No |
| Product function | | |
| | | No |
- passage automatique sur heure d'ete/heure d'hiver
| | No |
- programme temporel Vacances
| | No |
- preselection de commutation
| | No |
- programme temporel hebdomadaire
| | No |
| Temperature reglable | | |
- for frost protection / initial value
| °C | 40 |
- for comfort control / final value
| °C | 100 |
- for temperature lowering / initial value
| °C | 40 |
- pour protection antigel / valeur finale
| °C | 100 |
- pour reglage confort / valeur initiale
| °C | 40 |
- pour abaissement de temperature / valeur finale
| °C | 100 |
| Connection terminals / screw | | PZ 1 |
| Conductor cross-sections | | 1.5 to 6mm? (rigid); 0.75mm? (flexible, with end sleeve min.) |
| Permissible humidity | | <= 80% ( device) ; <=98% (temperature sensor ) |
| Permissible ambient temperature | | -10 till +55°C (device) ; -30 till +105°C (temperature sensor ) |
| Different phases / drive/contact permissible | | Yes |
| Rated impulse withstand voltage Uimp / (1.2/50 µs) | | > 2,5kW (drive/contact) |
| Galvanic isolation | | 4mm ( Creepage distances and clearances ) |
| Contact | | |
- rated operational current Is
| | 16A ( at p.f. = 1 ) ; 4A ( at p.f. = 0,4) |
- rated operational voltage Ue / AC
| V | 250 |
| Contacts / minimum contact loading | | 10V ; 100mA |
| Contact switching / (closes with increasing temperature) | | Terminals 3/4 |
| Switching hysteresis adjustable | | 1 till 5°C |
| Protection class / acc. to DIN EN 61010 | | II |
| Status display, LED | | green ( operating voltage ) ; red (Switching state ON) ; Red flashing ( Break or short circuit of the sensor conductor ) |
| |
| Certificates/approvals: |
| General Product Approval | | ROSTEST | | | | | | |
| |
| Further information: |
| Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/lowvoltage/catalogs |
| Industry Mall (Online ordering system) http://www.siemens.com/lowvoltage/mall |
| Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/7LQ2003/all |
| Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=7LQ2003 |
| CAx-Online-Generator http://www.siemens.com/cax |
| Tender specifications Datanorm GAEB81 GAEB83 RTF TXT |
| |
| |
| |
| last change: | Mar 13, 2012 |