| | COMMUNICATIONSPROCESSOR CP343-1 ADVANCED FOR CONNECTING SIMATIC S7-300CPU TO IND.ETHERNET: PROFINET IO- CONTROLLER OR/AND IO-DEVICE RT AND IRT, MRP, PROFINET CBA TCP/IP,ISO,UDP,S7-COM,S5-COMP. COM.(SEND/RECEIVE)W.FETCH/WRITE WIT AND W/O RFC 1006,MULTICAST DIAGNOSTIC EXPANSIONS,SNMP,DHCP FTP CLIENT/SERVER,E-MAIL, DATA STORAGE ON C-PLUG, PROFINET-SS 2X RJ45(10/100MBIT) SWITCHED, GIGABIT-SS 1X RJ45 (10/100/1000 MBIT) |
| Transmission rate | |
| Transfer rate | |
| | 10… 1000 Mbit/s |
| | 10… 100 Mbit/s |
| Interfaces | |
| Number of electrical connections | |
- at interface 1 / in accordance with Industrial Ethernet
| 1 |
- at interface 2 / in accordance with Industrial Ethernet
| 2 |
| | 1 |
| design of the removable storage / C-PLUG | Yes |
| Supply voltage, current consumption, power loss | |
| Type of voltage / of supply voltage | DC |
| Supply voltage | |
| | 5 V |
| | 24 V |
| Relative positive tolerance / at 24 V / with DC | 20 % |
| Relative negative tolerance / at 24 V / with DC | 15 % |
| Consumed current | |
- from backplane bus / at 5 V / for DC / [nicht versorgt - typisch]
| 0.14 A |
- [nicht versorgt - aus externer Versorgungsspannung] / [nicht versorgt - bei 24 V] / [nicht versorgt - bei DC]
| |
- [nicht versorgt - typisch]
| 0.48 A |
| | 0.62 A |
| Resistive loss | 14.7 W |
| Permitted ambient conditions | |
| Ambient temperature | |
| | -40… +70 °C |
| | -40… +70 °C |
| Relative humidity | |
- at 25 °C / without condensation / during operating / maximum
| 95 % |
| Protection class IP | IP20 |
| Design, dimensions and weight | |
| Width | 80 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Net weight | 0.6 kg |
| Performance data / open communication | |
| Number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum | 16 |
| Data volume | |
- as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum
| 8 Kibyte |
- as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum
| 8 Kibyte |
- as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum
| 8 Kibyte |
- as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum
| 2 Kibyte |
| Number of Multicast stations | 16 |
| Performance data / S7 communication | |
| Number of possible connections / [nicht versorgt - f?r S7-Kommunikation] | |
- [nicht versorgt - maximal]
| 16 |
| Performance data / multi-protocol mode | |
| Number of active connections / [nicht versorgt - bei Multiprotokollbetrieb] | 48 |
| Performance data / IT functions | |
| Number of possible connections | |
- [nicht versorgt - als Client] / [nicht versorgt - mittels FTP] / [nicht versorgt - maximal]
| 10 |
- [nicht versorgt - als Server]
| |
- [nicht versorgt - mittels FTP] / [nicht versorgt - maximal]
| 2 |
- [nicht versorgt - mittels HTTP] / [nicht versorgt - maximal]
| 4 |
- as e-mail client / maximum
| 1 |
| Amount of data / [nicht versorgt - als Nutzdaten f?r E-Mail] / [nicht versorgt - maximal] | 8 Kibyte |
| Storage capacity / of user memory | |
- as flash memory file system
| 28 Mibyte |
- [nicht versorgt - als RAM]
| 30 Mibyte |
| Number of possible write cycles / flash memory cells | 100000 |
| Performance data / PROFINET communication / as PN IO-Controller | |
| Number of PN IO-Devices / on PROFINET IO-Controller / usable / total | 128 |
| Number of PN IO IRT-Devices / on PROFINET IO-Controller / usable | 32 |
| Number of external PN IO lines / with PROFINET / per rack | 1 |
| Amount of data | |
- [nicht versorgt - als Nutzdaten f?r Eingangsvariablen] / [nicht versorgt - als PROFINET IO-Controller] / [nicht versorgt - maximal]
| 4 Kibyte |
- [nicht versorgt - als Nutzdaten f?r Eingangsvariablen] / [nicht versorgt - bei PROFINET IO-Controller] / [nicht versorgt - maximal]
| 4 Kibyte |
- [nicht versorgt - als Nutzdaten f?r Eingangsvariablen je PN IO-Device] / [nicht versorgt - bei PROFINET IO-Controller] / [nicht versorgt - maximal]
| 240 byte |
- [nicht versorgt - als Nutzdaten f?r Ausgangsvariablen je PN IO-Device] / [nicht versorgt - bei PROFINET IO-Controller] / [nicht versorgt - maximal]
| 240 byte |
- as user data for input variable per PN IO device / per submodule as PROFINET IO controller / maximum
| 240 byte |
- as user data for output variables per PN IO device / per submodule as PROFINET IO controller / maximum
| 240 byte |
| Performance data / PROFINET communication / as PN IO-Device | |
| Product function / PROFINET IO device | Yes |
| Amount of data | |
- [nicht versorgt - als Nutzdaten f?r Eingangsvariablen] / [nicht versorgt - als PROFINET IO-Device] / [nicht versorgt - maximal]
| 1024 byte |
- [nicht versorgt - als Nutzdaten f?r Eingangsvariablen] / [nicht versorgt - als PROFINET IO-Device] / [nicht versorgt - maximal]
| 1024 byte |
- [nicht versorgt - als Nutzdaten f?r Eingangsvariablen] / [nicht versorgt - je Submodul unter PROFINET IO-Device]
|
|