| | SIMATIC WINAC MP 2008 SOFTWARE SPS FOR MP277 PLATFORMS INCL. SINGLE LICENSE ON USB STICK INCL. ELECTRONIC DOCU |
| |
| Memory |
| Work memory |
| integrated | 256 kbyte |
| expandable | No |
| Load memory |
| integrated RAM, max. | 8 Mbyte |
| CPU-blocks |
| DB |
| Number, max. | 1024; FBs+FCs+DBs=1024 |
| Size, max. | 64 kbyte |
| FB |
| Number, max. | 1024; FBs+FCs+DBs=1024 |
| Size, max. | 64 kbyte |
| FC |
| Number, max. | 1024; FBs+FCs+DBs=1024 |
| Size, max. | 64 kbyte |
| OB |
| Number, max. | 18 |
| Size, max. | 64 kbyte |
| Number of free cycle OBs | 1; OB 1 |
| Number of time alarm OBs | 1; OB 10 |
| Number of delay alarm OBs | 1; OB 20 |
| Number of time interrupt OBs | 1; OB 35 |
| Number of process alarm OBs | 1; OB 40 |
| Number of startup OBs | 2; OB 100, 102 |
| Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 88 |
| Nesting depth |
| per priority class | 8 |
| additional within an error OB | 2 |
| Counters, timers and their retentivity |
| S7 counter |
| Number | 256 |
| of which retentive without battery |
| adjustable | Yes |
| lower limit | 0 |
| upper limit | 255 |
| Retentivity |
| adjustable | Yes |
| preset | 8 |
| Counting range |
| lower limit | 0 |
| upper limit | 999 |
| IEC counter |
| present | Yes; SFB0, SFB1, SFB2 |
| S7 times |
| Number | 256 |
| of which retentive without battery |
| adjustable | Yes |
| lower limit | 0 |
| upper limit | 255 |
| Retentivity |
| adjustable | Yes |
| preset | 0 |
| Time range |
| lower limit | 10 ms |
| upper limit | 9990 s |
| IEC timer |
| present | Yes; SFB3, SFB4, SFB5 |
| Data areas and their retentivity |
| retentive data area in total (incl. times, counters, flags), max. | 128 kbyte |
| Flag |
| Number, max. | 2 kbyte |
| Retentivity available | Yes |
| Data blocks |
| Number, max. | 1024 |
| Size, max. | 64 kbyte |
| Local data |
| per priority class, max. | 16384 byte; for all priority classes |
| Address area |
| I/O address area |
| Inputs | 4 kbyte |
| Outputs | 4 kbyte |
| of which, distributed |
| Inputs | 4 kbyte |
| Outputs | 4 kbyte |
| Process image |
| Inputs | 2 kbyte |
| Outputs | 2 kbyte |
| Inputs, adjustable | 2 kbyte |
| Outputs, adjustable | 2 kbyte |
| Inputs, default | 512 byte |
| Outputs, default | 512 byte |
| consistent data, max. | 32 byte |
| Hardware configuration |
| Number of DP masters |
| integrated | 1 |
| Time of day |
| Operating hours counter |
| Number | 8 |
| Number/Number range | 0 to 7 |
| 1st interface |
| DP master |
| Number of connections, max. | 8 |
| Services |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| Equidistance mode support | No |
| SYNC/FREEZE | Yes |
| Activation/deactivation of DP slaves | Yes |
| DPV1 | Yes |
| Transmission rate, max. | 12 Mbit/s |
| Number of DP slaves, max. | 32 |
| Address area |
| Inputs, max. | 4 kbyte |
| Outputs, max. | 4 kbyte |
| User data per DP slave |
| User data per DP slave, max. | 244 byte; Max. consistent user data length 32 bytes |
| Communication functions |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication |
| supported | No |
| S7 basic communication |
| supported | No |
| S7 communication |
| supported | Yes; PUT/GET, BSEND/BRCV, USEND/URCV |
| as server | Yes |
| as client | Yes |
| User data per job, max. | 480 byte |
| Number of connections |
| overall | 16; (max. 8 DP, rest PROFINET) |
| usable for PG communication | |
| reserved for PG communication | 1 |