6ES7416-2FK02-0AB0 - SIMATIC S7-400, CPU 416F-2 CENTRAL PROCESSING UNIT WITH: 1.6 MB WORKING MEMORY (0.8 MB CODE, 0.8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE DP, APPLICABLE W. SOFTWARE PACKAGE DISTRIBUTED SAFETY V5.2 (siemens) - Quad Industry GmbH
Артикул: 6ES7416-2FK02-0AB0
Наименование: SIMATIC S7-400, CPU 416F-2 CENTRAL PROCESSING UNIT WITH: 1.6 MB WORKING MEMORY (0.8 MB CODE, 0.8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE DP, APPLICABLE W. SOFTWARE PACKAGE DISTRIBUTED SAFETY V5.2 (siemens)
Производитель: Siemens
|
|
| | Наименование продукта SIMATIC S7-400, CPU 416F-2 CENTRAL PROCESSING UNIT WITH: 1.6 MB WORKING MEMORY (0.8 MB CODE, 0.8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE DP, APPLICABLE W. SOFTWARE PACKAGE DISTRIBUTED SAFETY V5.2 | | | | | Версия от 2012-02-18 | | | | | SIMATIC S7-400, CPU 416F-2 CENTRAL PROCESSING UNIT WITH: 1.6 MB WORKING MEMORY (0.8 MB CODE, 0.8 MB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE DP, APPLICABLE W. SOFTWARE PACKAGE DISTRIBUTED SAFETY V5.2 | | | | CiR - Configuration in RUN | | CiR synchronization time, basic load | 100 ms | | CiR synchronization time, time per I/O slave | 120 µs | | Input current | | from backplane bus 5 V DC, typ. | 1.5 A | | from backplane bus 5 V DC, max. | 1.6 A | | from backplane bus 24 V DC, max. | 300 mA; Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface | | Power losses | | Power loss, typ. | 7.5 W | | Backup battery | | Battery operation | | | Backup current, typ. | 40 µA | | Backup current, max. | 420 µA | | Memory | | Work memory | | integrated | 1.6 Mbyte; 0.8 MB for program; 0.8 MB for data | | Load memory | | expandable FEPROM | with Memory Card (FLASH) | | expandable FEPROM, max. | 64 Mbyte | | integrated RAM, max. | 256 Kibyte | | expandable RAM | with Memory Card (RAM) | | expandable RAM, max. | 64 Mbyte | | Backup | | with battery | all data | | CPU processing times | | for bit operations, min. | 0.08 µs | | for word operations, min. | 0.08 µs | | for fixed point arithmetic, min. | 0.08 µs | | for floating point arithmetic, min. | 0.48 µs | | CPU-blocks | | DB | | Number, max. | DB 0 reserved | | Size, max. | 64 Kibyte | | FB | | Size, max. | 64 Kibyte | | FC | | Size, max. | 64 Kibyte | | OB | | Size, max. | 64 Kibyte | | Counters, timers and their retentivity | | S7 times | | Time range | | lower limit | 10 ms | | upper limit | 9990 s | | Data areas and their retentivity | | Flag | | Number, max. | 16 Kibyte | | Retentivity available | MB 0 to MB 16383 | | Number of clock memories | 1 memory byte | | Data blocks | | Number, max. | DB 0 reserved | | Size, max. | 64 Kibyte | | Address area | | I/O address area | | Inputs | 16 Kibyte | | Outputs | 16 Kibyte | | of which, distributed | | MPI/DP interface, inputs | 2 Kibyte | | MPI/DP interface, outputs | 2 Kibyte | | DP interface, inputs | 8 Kibyte | | DP interface, outputs | 8 Kibyte | | Process image | | Inputs, adjustable | 16 Kibyte | | Outputs, adjustable | 16 Kibyte | | Inputs, default | 512 byte | | Outputs, default | 512 byte | | consistent data, max. | 244 byte | | Hardware configuration | | Expansion devices, max. | (of which 6 ER with K-bus) | | Multicomputing | Max. 4 CPUs (with UR1 or UR2) | | Number of DP masters | | via CP | CP 443-5 Extended | | Mixed mode IM + CP permitted | IM 467 cannot be used jointly with CP 443-5 Ext. | | Number of operable FMs and CPs (recommended) | | FM | Limited by number of slots and number of connections | | CP, point-to-point | limited by number of slots | | CP, LAN | limited by number of connections | | PROFIBUS and Ethernet CPs | incl. CP 443-5 Ext. and IM 467 | | Time of day | | Clock | | Resolution | 1 ms | | 1st interface | | MPI | | Services | | Transmission rate, max. | 12 Mbit/s | | DP master | | Services | | Transmission rate, max. | 12 Mbit/s | | Address area | | Inputs, max. | 2 Kibyte | | Outputs, max. | 2 Kibyte | | User data per DP slave | | Inputs, max. | 244 byte | | Outputs, max. | 244 byte | | per slot, max. | 128 byte | | DP slave | | Services | | PG/OP communication | with interface active | | Routing | with interface active | | Transmission rate, max. | 12 Mbit/s | | Transfer memory | | Inputs | 244 byte | | Outputs | 244 byte | | User data per address area, max. | 32 byte | | User data per address area, of which consistent, max. | 32 byte | | 2nd interface | | DP master | | Services | | Transmission rate, max. | 12 Mbit/s | | Address area | | Address area, max. | 8 Kibyte | | Inputs, max. | 8 Kibyte | | Outputs, max. | 8 Kibyte | | User data per DP slave | | Inputs, max. | 128 byte | | Outputs, max. | 128 byte | | DP slave | | Services | | Routing | with interface active | | Transmission rate, max. | 12 Mbit/s | | Transfer memory | | Inputs | 244 byte | | Outputs | 244 byte | | User data per address area, max. | 32 byte | | User data per address area, of which consistent, max. | 32 byte | | Isochronous mode | | User data per isochronous slave, max. | Назад в раздел
|
| | |