| | SIMATIC S7-300, COUNTER MODULE FM 350-1 FOR S7-300, COUNTER FUNCTIONS UP TO 500 KHZ 1 CHANNEL FOR CONNECTION OF 5V AND 24V INCREMENTAL ENCODERS INCL. CONFIG. PACKAGE ON CD |
| |
| Supply voltage |
| Aux. voltage 1L+, load voltage 2 L+ |
| Rated value (DC) | 24 V |
| Permissible range (ripple included) |
| dynamic, lower limit (DC) | 18.5 V |
| dynamic, upper limit (DC) | 30.2 V |
| static, lower limit (DC) | 20.4 V |
| static, upper limit (DC) | 28.8 V |
| non-periodic skip |
| Duration | 500 ms |
| Recovery time | 50 s |
| Value | 35 V |
| Input current |
| from load voltage 1L+ (without load), max. | 40 mA |
| from backplane bus 5 V DC, max. | 160 mA |
| Encoder supply |
| 5 V encoder supply |
| 5 V | Yes; 5.2 V +/-2% |
| Output current, max. | 300 mA |
| 24 V encoder supply |
| 24 V | Yes; 1L+ (-3 V) |
| Output current, max. | 300 mA |
| Power losses |
| Power loss, typ. | 4.5 W |
| Digital inputs |
| Number/binary inputs | 3 |
| Functions | 1 for gate start, 1 for gate stop, 1 for setting the counter |
| Input voltage |
| for signal "0" | -28.8 to +5 V |
| for signal "1" | +11 to +28.8 V |
| Input current |
| for signal "1", typ. | 9 mA |
| Digital outputs |
| Number/binary outputs | 2 |
| Functionality/short-circuit strength | Yes; Clocked electronically |
| Limitation of inductive shutdown voltage to | 2L+ (-39 V) |
| Output voltage |
| for signal "0", max. | 3 V |
| for signal "1", min. | 2L+ (-1.5 V) |
| Output current |
| for signal "1" rated value | 0.5 A |
| for signal "1" permissible range for 0 to 60 °C, min. | 5 mA |
| for signal "1" permissible range for 0 to 60 °C, max. | 0.6 A |
| Output delay with resistive load |
| 0 to "1", max. | 300 µs |
| Encoder |
| Connectable encoders |
| Incremental encoder (symmetrical) | Yes; With 2 pulse trains offset by 90° |
| Incremental encoder (asymmetrical) | Yes |
| 24 V initiator | Yes |
| 24 V directional element | Yes; 1 pulse train, 1 direction level |
| Counter |
| Number of counter inputs | 1 |
| Counting range, description | 32 bit or +/-31 bit |
| Minimum pulse width, adjustable | Yes; 2.5 or 25 µs |
| Counter input 5 V |
| Type | RS 422 |
| Terminating resistor | 220 Ω |
| Differential input voltage | 0.5 V |
| Counting frequency, max. | 500 kHz |
| Counter input 24 V |
| Input voltage, for signal "0" | -28.8 to +5 V |
| Input voltage, for signal "1" | +11 to +28.8 V |
| Input current, for signal "1", typ. | 9 mA |
| Counting frequency, max. | 200 kHz |
| Minimum pulse width | 2.5 µs |
| Parameter |
| Remark | assigned binary addresses: 16 bytes |
| Galvanic isolation |
| Galvanic isolation digital inputs |
| between the channels and the backplane bus | Yes; Optocoupler |
| Galvanic isolation digital outputs |
| between the channels and the backplane bus | Yes; Optocoupler |
| Galvanic isolation counter |
| between the channels and the backplane bus | Yes; Optocoupler |
| Permissible potential difference |
| between different circuits | 75 VDC / 60 VAC |
| Isolation |
| Isolation checked with | 500 V |
| Connection method |
| required front connector | 1x 20-pin |
| Dimensions |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Weight |
| Weight, approx. | 250 g |
| Status | Mar 12, 2012 |