6ES7144-4JF00-0AB0 - SIMATIC DP, ELECTRONIC MODULES FOR ET200PRO 4 AI RTD HIGH FEATURE, PT100; PT200; PT500; PT1000; NI100; NI200; NI500; NI1000; CHANNEL DIANOSTICS; INCLUSIVE BUS MODULE, CONNECTING MODULE IO 6ES7194-4..00-0AA0 MUST BE ORDERED SEPERATELY (siemens) - Quad Industry GmbH

Артикул: 6ES7144-4JF00-0AB0
Наименование: SIMATIC DP, ELECTRONIC MODULES FOR ET200PRO 4 AI RTD HIGH FEATURE, PT100; PT200; PT500; PT1000; NI100; NI200; NI500; NI1000; CHANNEL DIANOSTICS; INCLUSIVE BUS MODULE, CONNECTING MODULE IO 6ES7194-4..00-0AA0 MUST BE ORDERED SEPERATELY (siemens)
Производитель: Siemens


Наименование продукта
SIMATIC DP, ELECTRONIC MODULES FOR ET200PRO 4 AI RTD HIGH FEATURE, PT100; PT200; PT500; PT1000; NI100; NI200; NI500; NI1000; CHANNEL DIANOSTICS; INCLUSIVE BUS MODULE, CONNECTING MODULE IO 6ES7194-4..00-0AA0 MUST BE ORDERED SEPERATELY
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2006-02-28
Manuals weitere>>
Distributed I/O device ET 200pro  2005-12-16
SIMATIC DP, ELECTRONIC MODULES FOR ET200PRO 4 AI RTD HIGH FEATURE, PT100; PT200; PT500; PT1000; NI100; NI200; NI500; NI1000; CHANNEL DIANOSTICS; INCLUSIVE BUS MODULE, CONNECTING MODULE IO 6ES7194-4..00-0AA0 MUST BE ORDERED SEPERATELY
Supply voltage
Load voltage L+
Rated value (DC) 24 V
Reverse polarity protection Yes; against destruction
Input current
from backplane bus 3.3 V DC, max. 10 mA; typ.
Power losses
Power loss, typ. 0.7 W
Address area
Address space per module
Address space per module, max. 8 byte
Analog inputs
Number of analog inputs 4
Cycle time (all channels) max. 83 ms; 83 ms at 50 Hz; 69 ms at 60 Hz
Technical unit for temperature measurement adjustable Yes
Input ranges
Voltage No
Current No
Thermocouple No
Resistance thermometer Yes
Resistance Yes
Input ranges (rated values), resistance thermometers
Cu 10 No
Ni 100 Yes
Input resistance (Ni 100) 10000 kΩ
Ni 1000 Yes
Input resistance (Ni 1000) 10000 kΩ
Ni 120 Yes
Input resistance (Ni 120) 10000 kΩ
Ni 200 Yes
Input resistance (Ni 200) 10000 kΩ
Ni 500 Yes
Input resistance (Ni 500) 10000 kΩ
Pt 100 Yes
Input resistance (Pt 100) 10000 kΩ
Pt 1000 Yes
Input resistance (Pt 1000) 10000 kΩ
Pt 200 Yes
Input resistance (Pt 200) 10000 kΩ
Pt 500 Yes
Input resistance (Pt 500) 10000 kΩ
Input ranges (rated values), resistors
0 to 150 ohms Yes
Input resistance (0 to 150 ohms) 10000 kΩ
0 to 300 ohms Yes
Input resistance (0 to 300 ohms) 10000 kΩ
0 to 600 ohms Yes
Input resistance (0 to 600 ohms) 10000 kΩ
0 to 3000 ohms Yes
Input resistance (0 to 3000 ohms) 10000 kΩ
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer Ptxxx, Nixxx
Characteristic linearization
Parameterizable Yes
Cable length
Cable length, shielded, max. 30 m
Analog value creation
Measurement principle integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max. 15 bit; at 150, 300, 600 und 3000 ohms; otherwise 15 bits + sign
Integration time, ms 20 / 16,667
Interference voltage suppression for interference frequency f1 in Hz 50/60 Hz
Conversion time (per channel) 20.625 ms; 20.625 ms at 50 Hz; 17.25 ms at 60 Hz
Smoothing of measured values
Parameterizable Yes
Step: None Yes; 1 x cycle time
Step: low Yes; 4 x cycle time
Step: Medium Yes; 16 x cycle time
Step: High Yes; 64 x cycle time
Encoder
Connection of signal encoders
for resistance measurement with 2-conductor connection Yes; Line resistances are also measured
for resistance measurement with 3-conductor connection Yes
for resistance measurement with 4-conductor connection Yes
Errors/accuracies
Linearity error (relative to input area) +/- 0.05 %
Temperature error (relative to input area) +/- 0.002 %/K
Crosstalk between the inputs, min. -50 dB
Repeat accuracy in settled status at 25 °C (relative to input area) +/- 0.015 %
Operational limit in overall temperature range
Resistance-type thermometer, relative to input area +/- 0.175 %
Basic error limit (operational limit at 25 °C)
Resistance-type thermometer, relative to input area +/- 0.125 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min. 50 dB
common mode voltage (USS < 2.5 V) , min. 70 dB; Interference voltage < 5 V
Interrupts/diagnostics/status information
Diagnostic messages
Wire break Yes
Group error Yes
Overflow/underflow Yes
Diagnostics indication LED
Group error SF (red) Yes
Parameter
Diagnosis: wire break 1
Load voltage No
Measurement type/range R4L / R3L / R2L/ TR4L / TR3L / TR2L
Interference frequency suppression 50/60 Hz
Group diagnostics 1
Overflow/underflow 1
Unit Degrees C / Degrees F
Galvanic isolation
Galvanic isolation analog inputs
between the channels No
between the channels and the backplane bus Yes
Permissible potential difference
between the inputs (UCM) 5 Vpp AC
between MANA and M internally (UISO) 500 V DC
Isolation
Isolation checked with Назад в раздел