| | SIMATIC DP, ELECTRONIC BLOCK FOR ET 200L, 16 DO, 24V DC/0.5A |
| |
| General information |
| Vendor identification (VendorID) | 0016h |
| Supply voltage |
| 24 V DC | Yes |
| Reverse polarity protection | Yes |
| Mains buffering |
| Mains buffering, min. | 20 ms |
| Load voltage 2L+ |
| Rated value (DC) | 24 V; 1L+, 2L+, 3L+ |
| Input current |
| from load voltage L1 (without load), max. | 50 mA; Per load group (L1+ or L2+ / L3+) |
| from supply voltage L+, max. | 70 mA; L4+ / L5+ |
| Power losses |
| Power loss, typ. | 5 W |
| Hardware configuration |
| Rack |
| Required terminal block | TB 16L |
| Digital outputs |
| Number/binary outputs | 16 |
| Functionality/short-circuit strength | Yes; Electronic |
| Response threshold, typ. | 0.7 A |
| Limitation of inductive shutdown voltage to | Typ. (L1+ or L2+ / L3+) -55 V |
| Lamp load, max. | 5 W |
| Controlling a digital input | Yes |
| Load resistance range |
| lower limit | 41 Ω |
| upper limit | 28000 Ω |
| Output voltage |
| Rated value (DC) | 24 V |
| for signal "1", min. | Ua - 3 V |
| Output current |
| for signal "1" rated value | 0.5 A |
| for signal "1" permissible range for 0 to 60 °C, max. | 0.5 A |
| for signal "0" residual current, max. | 1 mA |
| Output delay with resistive load |
| 0 to "1", max. | 50 ms |
| 1 to "0", max. | 200 ms |
| Parallel switching of 2 outputs |
| for increased power | No |
| for redundant control of a load | Yes; only outputs of the same group |
| Switching frequency |
| with resistive load, max. | 100 Hz |
| with inductive load, max. | 0.5 Hz |
| on lamp load, max. | 8 Hz |
| Aggregate current of outputs (per group) |
| all mounting positions |
| up to 60 °C, max. | 4 A |
| all other mounting positions |
| up to 40 °C, max. | 2 A |
| Cable length |
| Cable length, shielded, max. | 1000 m |
| Cable length unshielded, max. | 600 m |
| Interfaces |
| PROFIBUS DP |
| Transmission rate, max. | 1.5 Mbit/s |
| SYNC capability | Yes |
| Direct data exchange (slave-to-slave communication) | Yes; Transmitter (for digital outputs and hybrid modules ET 200L: not for L-SC or IM-SC) |
| Communication functions |
| Bus protocol/transmission protocol | PROFIBUS DP |
| Interrupts/diagnostics/status information |
| Alarms |
| Alarms | No |
| Diagnostic messages |
| Diagnostic functions | Yes |
| Diagnostics indication LED |
| Bus fault BF (red) | Yes |
| Status indicator digital output (green) | Yes |
| Status indicator digital input (green) | Yes |
| Monitoring 24 V voltage supply ON (green) | Yes |
| Galvanic isolation |
| between PROFIBUS DP and all other circuit components | Yes |
| Galvanic isolation digital outputs |
| between the channels | No |
| between the channels and PROFIBUS DP | Yes; Optocoupler |
| Isolation |
| Isolation checked with | 500 V DC |
| Ambient conditions |
| Operating temperature |
| horizontal installation, min. | 0 °C |
| horizontal installation, max. | 60 °C; 40°C for other mountings |
| Air pressure |
| permissible range, min. | 795 hPa |
| permissible range, max. | 1080 hPa |
| Relative humidity |
| Operation, min. | 5 % |
| Operation, max. | 95 %; RH class 2 in accordance with IEC 1131-2 |
| Vibrations |
| Operation, checked according to IEC 60068-2-6 | Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) |
| Shock test |
| checked according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms |
| Degree and class of protection |
| IP20 | Yes |
| Connection method |
| Inputs/outputs | Screw-type and spring-loaded terminals, permanent wiring; standard: 2-wire connection, optional: 3 and 4-wire connection |
| Dimensions |
| Width | 145 mm |
| Height | 60 mm |
| Depth | 60.5 mm |
| Weight |
| Weight, approx. | 130 g |
| Status | Mar 12, 2012 |