| | SIPLUS CMS1000 BEARING GUARD; ROLLER BEARING AND MASCHINE MONITORING BASED ON CHARACTERISTIC VALUES; K(T) ACCORDING TO VDI3832 AND RMS ACCORDING TO DIN ISO 10816-3; 1*CMS1000-SENSOR INTERFACE; 1*SPEED ROTATION INPUT; 2*POTENTIAL FREE OUTPUT CONTACTS FOR WARNING AND ALARM; UB=24VDC; 115VAC UP TO 240VAC |
| |
| General technical data: |
| Product brand name | | SIPLUS |
| product designation | | SIPLUS CMS1000 Bearing Guard |
| Protection class IP | | IP20 |
| Ambient temperature | | |
| | °C | -25… 60 |
| | °C | -25… 60 |
| | °C | -25… 60 |
| Active power loss / total / typical | W | 3.5 |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | P |
- according to DIN EN 61346-2
| | P |
| |
| Supply voltage: |
| Type of voltage / of supply voltage | | AC/DC |
| Supply voltage / 1 / for DC / rated value | V | 24 |
| Supply voltage / 1 | | |
| | | |
| | V | 115… 240 |
| | | |
| | V | 115… 240 |
| |
| Installation/mounting/dimensions: |
| Built in orientation | | vertical |
| | | vertical |
| Type of mounting | | standard rail |
| Width | mm | 45 |
| Height | mm | 106 |
| Depth | mm | 86 |
| |
| Inputs/ Outputs: | | |
| Number of sensor inputs | | |
| | | 0 |
| | | 1 |
| Number of disable inputs | | 1 |
| Design of input / disable input / DC 24 V | | Yes |
| Number of rotational speed inputs | | 1 |
| Input voltage / rotational speed input / DC 24 V digital | | Yes |
| Range of input voltage / rotational speed input / -10 V ... + 10 V | | Yes |
| Range of input current / rotational speed input | | |
| | | No |
| | | Yes |
| Number of indicator outputs | | 2 |
| Design of output / indicator output | | Relay output |
| |
| Connections: |
| Design of the electrical connection / of the inputs and outputs | | screw terminal |
| |
| terminals |
| Product function / removable terminal for main circuit | | Yes |
| Design of the electrical connection / for auxiliary and control current circuit | | screw-type terminals |
| Product function / removable terminal for auxiliary and control circuit | | Yes |
| Conductor cross-section that can be connected / for auxiliary contact | | |
| | mm? | 0.5… 4 |
| | | |
- with conductor end processing
| mm? | 0.5… 2.5 |
- without conductor final cutting
| mm? | 0.5… 2.5 |
| |
| Communication: | | |
| Product function / bus-communication | | No |
| |
| Certificates/approvals: |
| Verification of suitability | | CE |
| |
| |
| Further information: |
| Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs |
| Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall |
| CAx-Online-Generator http://www.siemens.com/cax |
| Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/6AT8001-1AA00/all |
| Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=6AT8001-1AA00 |
| |
| |
| | |
| |
| last change: | Oct 24, 2011 |