| | SINVERT PVS1000 PV-INVERTER, 600SERIES, IEC 50HZ, 3P NOM. ACTIVE POWER (AC):1000KVA GRID CONNECT. MV TRANS, MPP-RANGE: 450-750V, UMAX 820VDC, 6 DC-INPUTS, IP20, AIR COOLING, INVERTER UNIT AMOUNT: 2, OPTIONS AVAILABLE. FOR: 1000V-OPTION (UDCMAX 1000V), PV FIELD POSITIVE GROUNDING, PV FIELD MINUS GROUNDING , SYMMETRY MONITORING, CABINET HEATING, SINVERT PVS WARRANTY 5 YEARS, |
| |
| General technical data: |
| Output class for PV inverters | | 1000 |
| Efficiency | | |
| | % | 98.4 |
| | % | 98.3 |
| | % | 98.3 |
| Design of PV inverter unit | | master-slave combination |
| Number of PV inverter sub-units | | 2 |
| Type of installation | | indoor installation |
| Protection class IP | | IP20 |
| Operating resource protection class | | I |
| Design of the interface / for communication | | Ethernet |
| A-rated sound power level / maximum | dB | 80 |
| Design of the display | | LCD-TFT |
| National language / at the indicator of the display / selectable | | English, German |
| Connection method for PV inverters | | without transformer |
| |
| Output (AC side): | | |
| Phase number | | 3 |
| Output voltage / on the AC side / for infeed operation | | |
| | V | 288 |
| | V | 244.8 |
| | V | 316.8 |
| Power factor / at nominal value of active power supplied / nominal value | | 1 |
| Power factor inductive | | 0.8 |
| Power factor capacitive | | 0.8 |
| Active power supplied / on the AC side | | |
- in permanent operation / nominal value
| W | 1,000,000 |
| | W | 1,000,000 |
| Current supplied / on the AC side / maximum | A | 2,004 |
| Line frequency / suitable for infeed operation | | |
| | Hz | 50 |
| | Hz | 47.5 |
| | Hz | 51.5 |
| Relative residual ripple / of AC current / at nominal value of the AC active power / on unloaded line / maximum | % | 2 |
| Grounding concept / on the AC side | | IT |
| Design of the overvoltage protection / on the AC side | | type 1/2 |
| |
| Input (DC side): | | |
| MPP voltage | V | 450… 750 |
| Consumed active power / on the DC side / nominal value | W | 1,026,000 |
| Input voltage / on the DC side | | |
- for the start of the infeed operation
| V | 600 |
- for possible infeed operation
| V | 450… 750 |
| | V | 465 |
| | V | 820 |
| Number of inputs / on the DC side | | 6 |
| Input current / per DC input / maximum | A | 368 |
| Total power used / on the DC side / maximum | A | 2,206 |
| Overcurrent strength / per DC input / nominal value | A | 368 |
| Product component / on the DC side / overvoltage protection per DC input | | Yes |
| Design of the overvoltage protection / on the DC side | | type 2 |
| |
| External auxiliary voltage supply: | | |
| Auxiliary voltage / nominal value | V | 400 |
| Auxiliary voltage frequency / nominal value | Hz | 50 |
| effective power consumed / from external auxiliary supply | | |
- for infeed mode / without cabinet heating / maximum
| W | 5,300 |
- for infeed mode / with cabinet heating / maximum
| W | 5,800 |
- in night-time operating mode
| | |
- without cabinet heating / maximum
| W | 380 |
- with cabinet heating / maximum
| W | 880 |
| Grounding concept / for auxiliary power supply external | | TN-S |
| |
| Ambient conditions: | | |
| Installation altitude | | |
| | m | 0… 1,000 |
| | m | 2,000 |
| Incoming air temperature / at nominal value of active power supplied / maximum | °C | 40 |
| Ambient temperature | | |
| | °C | 0… 50 |
| | °C | -25… +70 |
| | °C | -25… +70 |
| Relative humidity | | |
| | % | 0… 95 |
| | % | 0… 95 |
| | % | 0… 95 |
| Climatic class | | 3K3 |
| Type of cooling | | forced-air cooling via fan |
| Cooling air flow | m³/h | 13,000 |
| Nature of the ventilation | | air intake cabinet front/air outlet cabinet top |
| |
| Mechanical data: | | |
| Width / of PV inverter subunits | mm | 2,700 |
| Height / of PV inverter subunits | mm | 2,100 |
| Depth / of PV inverter subunits | mm | 730 |