промышленная комутационная техника
| Артикул |
Наименование |
Производитель |
|
4AM3452-1TB50-0AD0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,32; UPRI(V):230; USEC(V):190-175-150-125-100-80; ISEC(A):1,68 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM3452-1TB50-0AC0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,36; UPRI(V):230; USEC(V):190-175-150-125-100-80; ISEC(A):1,9 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13>UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM3452-1TB50-0AA0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,4; UPRI(V):230; USEC(V):190-175-150-125-100-80; ISEC(A):2,1 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8MD40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):440-400-230; USEC(V):230(2X115); ISEC(A):0,435-0,870; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8MB40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):440-400-230; USEC(V):48(2X24); ISEC(A):2,08-4,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8LT10-0FS1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230; USEC(V):230; ISEC(A):0,43; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4 (siemens)
|
Siemens
|
|
4AM3442-8JX00-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):48; ISEC(A):2,083; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JV00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):1,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JV00-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):2,14; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 (siemens)
|
Siemens
|
|
4AM3442-8JV00-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):2,38; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0ED1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0EC1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,75; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,75; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-6 >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0EA1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):4,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):4,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JD40-0FD1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X0,35; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JD40-0FD0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X0,35; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JD40-0FC1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X0,39; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JD40-0FC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X0,39; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JD40-0FA1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):0,435-0,870; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JD40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X0,43; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JB40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):48-2X24; ISEC(A):2,08;4,16; F(HZ):50...50; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM3442-8JA40-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):24-12 (2X12); ISEC(A):4,167-8,333; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8EV00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):600-575-550-525-500- 480-460-440-415-400-240-230; USEC(V):42; ISEC(A):1,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 (siemens)
|
Siemens
|
|
4AM3442-8EV00-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):600-575-550-525-500- 480-460-440-415-400-240-230; USEC(V):42; ISEC(A):2,14; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 (siemens)
|
Siemens
|
|
4AM3442-8EV00-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):600-575-550-525-500- 480-460-440-415-400-240-230; USEC(V):42; ISEC(A):2,38; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-6 (siemens)
|
Siemens
|
|
4AM3442-8ET10-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):600-575-550-525-500- 480-460-440-415-400-240-230; USEC(V):230; ISEC(A):0,435; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8EN00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):600-575-550-525-500- 480-460-440-415-400-240-230; USEC(V):24; ISEC(A):3,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8EN00-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):600-575-550-525-500- 480-460-440-415-400-240-230; USEC(V):24; ISEC(A):3,75; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
Товары
12331 - 12360 из 13660
Начало
|
Пред.
|
410
411
412
413
414
|
След. |
Конец
|