4AM4096-0EU40-0AA0 AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,46; UPRI(V):460-400; USEC(V):230; ISEC(A):2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-13 >UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0EU10-0FA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):460-400+/-20; USEC(V):230( 80VA); 24 (170VA); ISEC(A):0,35 ; 7,08; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0EU00-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,2 /0,8; UPRI(V):480-460-415-380-230- 208-200; USEC(V):200( 100VA); 24 (100VA); ISEC(A):0,5 ; 4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ET80-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):264; USEC(V):230; ISEC(A):1,09; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1;-2-2; -2-4 >UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0ET70-2EA0 SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,254; UPRI(V):230; USEC(V):16,1-0-16,1; ISEC(A):7,89-0-7,89; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:60 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens) Siemens
4AM4096-0ET60-0NA0 CONVERTER; PHASES:1; UPRI(V):5V/2A; USEC(V):25; ISEC(A):0,4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 615582-1>UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0ET50-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):220; USEC(V):55-0-55; ISEC(A):2,27-0-2,27; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1;-2-2; -2-4 >UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0ET40-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):660+/-5%; USEC(V):400 ( 200-0-200) ; 230; ISEC(A):0,375 ; 0,435; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>CONTROL CIRCUIT TRANSFORMER<>ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ET30-0EA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):380+/-5%; USEC(V):25; ISEC(A):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens) Siemens
4AM4096-0ET20-0EA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):240+/-5%; USEC(V):26; ISEC(A):9,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens) Siemens
4AM4096-0ET10-0FA0 MAINS TRANSFORMER; PHASES:1; PN(KVA):1,32; UPRI(V):500-380; USEC(V):110; ISEC(A):12 (KB 1,5% ED); F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0ET00-0FA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,22 /0,74; UPRI(V):460-400+/-20; USEC(V):230; 24; ISEC(A):0,435 ; 5,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ES80-0EN1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,211 /0,6; UPRI(V):400+/-5%; USEC(V):115-24; ISEC(A):1,0-4,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 (siemens) Siemens
4AM4096-0ES70-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):220; USEC(V):350-325-300; ISEC(A):0,714 KONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1; -2-2; -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ES60-0FA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):460-400+/-20; USEC(V):110; ISEC(A):2,27; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1; -2-2; -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ES50-0FA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):480-460-440-420-400- 380; USEC(V):110; ISEC(A):2,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0ES40-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,21 /0,75; UPRI(V):500-440-380-220; USEC(V):220;32-30-28; ISEC(A):0,455; 3,44 KONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ES00-0EN1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,211 /0,77; UPRI(V):400+/-5%; USEC(V):115-24; ISEC(A):1,0-4,00; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ER70-0EA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):280; USEC(V):24; ISEC(A):10,417; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens) Siemens
4AM4096-0ER60-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):280; USEC(V):230; ISEC(A):1,09; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ER50-0AA0 AUTOTRANSFORMER; PHASES:1; PN,D(KVA):1,6; UPRI(V):240+/-5%; USEC(V):230-220; ISEC(A):7 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens) Siemens
4AM4096-0ER40-0EA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):400; USEC(V):35-33-31; ISEC(A):7,14 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1; -2-2; -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens) Siemens
4AM4096-0ER30-0FA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):690+/-20V; USEC(V):230; ISEC(A):1,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>CONTROL CIRCUIT TRANSFORMER<>ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0ER20-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,18 /0,6; UPRI(V):690-600-500-480-460- 440-420-400-380-230-208; USEC(V):115;115;24; ISEC(A):0,7-0,7-0,83; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:45 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 (siemens) Siemens
4AM4096-0ER10-0EA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):100;100; USEC(V):24; ISEC(A):10,42; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1; -2-2; -2-6>UL/CSA-RECOGNIZED< (siemens) Siemens
4AM4096-0ER00-0FA0 ISOLATION TRANSFORMER; PHASES:1; PN(KVA):1,2; UPRI(V):240-220; USEC(V):40-20 ( 2X20 ); ISEC(A):30-60 ( 2X30 ) AB 4% ED; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>ISOLATION TRANSFORMER< (siemens) Siemens
4AM4096-0EQ80-0ES1 SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,225; UPRI(V):230; USEC(V):24; ISEC(A):9,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 (siemens) Siemens
4AM4096-0EQ70-0EA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,25 /0,85; UPRI(V):460-400+/-20; USEC(V):24; ISEC(A):10.4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens) Siemens
4AM4096-0EQ50-0NA0 MAINS TRANSFORMER; PHASES:1; PN(KVA):0,05; UPRI(V):1000-800-600; USEC(V):95(LEERMAX.100); ISEC(A):0,53; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1>MAINS TRANSFORMER< (siemens) Siemens
4AM4096-0EQ30-0CS1 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,25 /0,89; UPRI(V):400+/-5%; USEC(V):230;15; ISEC(A):0,91;2,67(EFF.); F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0I0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2 (siemens) Siemens