промышленная комутационная техника
| Артикул |
Наименование |
Производитель |
|
4AM4696-0AD00-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,24 /0,312; UPRI(V):230+/-3%-115; USEC(V):0-NACHB; ISEC(A):3-0-3; 2-0-2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0/6 /1; TA/ISOKL:50 /B; IP20; TYPE OF TERMINALS:FREE CONDUCTOR ENDS; INSTALLATION:SCREW; EN 61558-2-4>ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4696-0AC60-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,35 /1,54; UPRI(V):400+/-5%; USEC(V):230(0,86A);24(6,3A); ISEC(A):0,86-6,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:70 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4696-0AB30-0NA0
|
CONVERTER; PHASES:1; UPRI(V):0-2A; USEC(V):0-10A; ISEC(A):1% N>20; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN61558 >MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM4695-0AP80-0CN2
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,4 /1,45; UPRI(V):400-230; USEC(V):230; ISEC(A):1,74; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-4>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4692-8AA20-0NA0
|
TRANSFORMATOR F. MED. GERAETE; PHASES:1; PN(KVA):0,34; UPRI(V):400; IPRI(A):0,99; USEC(V):230; 190; 23,5; ISEC(A):0,56; 0,53; 4,68; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 60601-1 (siemens)
|
Siemens
|
|
4AM4691-0AA68-0J
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,328; UPRI(V):400; USEC(V):190; 23,5; ISEC(A):0,8 (70%ED); 7,5 (70%ED); F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /1; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 60601-1 (siemens)
|
Siemens
|
|
4AM4691-0AA28-1N
|
TRANSFORMATOR F. MED. GERAETE; PHASES:1; PN(KVA):248; UPRI(V):208-+16-23%TOLERANZ; IPRI(A):1,37; USEC(V):32-22-22; ISEC(A):5-2-2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /1; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 60601-1 (siemens)
|
Siemens
|
|
4AM4691-0AA20-1N
|
TRANSFORMATOR F. MED-RAEUME; PHASES:1; PN(KVA):248; UPRI(V):208; IPRI(A):1,37; USEC(V):32(5,0A);22(2,0A); 22(2,0A); ISEC(A):5-2-2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /1; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 60601-1 (siemens)
|
Siemens
|
|
4AM4661-6CB00-0AN2
|
CONVERTER; PHASES:1; UPRI(V):100; USEC(V):57,7; ISEC(A):0,0173; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIO /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN61558 >MAINS TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4646-3CB00-0AA0
|
CONVERTER; PHASES:1; UPRI(V):173-100; USEC(V):24; ISEC(A):0,125; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:45 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM4642-8MD40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):440-400-230; USEC(V):230(2X115); ISEC(A):1,74-3,48; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8MB40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):440-400-230; USEC(V):48(2X24); ISEC(A):8,33-16,7; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JX00-0FB0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,405; UPRI(V):400-230+/-15; USEC(V):48; ISEC(A):8,35; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM4642-8JX00-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):48; ISEC(A):8,333; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JV00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,3 /1,44; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):7,14; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 (siemens)
|
Siemens
|
|
4AM4642-8JV00-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,34 /1,44; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):8,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 (siemens)
|
Siemens
|
|
4AM4642-8JV00-0EB0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):9,52; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JV00-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):9,52; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0ED1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,3 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):12,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,3 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):12,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0EC1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,34 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):14,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,34 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):14,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0EB1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):16,7; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0EB0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):16,667; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:MOUNTING RAILS; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0EA1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):16,7; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JN00-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,4 /1,44; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):16,667; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JD40-0FD1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,3 /1,44; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X1,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JD40-0FD0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,3 /1,44; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X1,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JD40-0FC1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,34 /1,44; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X1,48; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM4642-8JD40-0FC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,34 /1,44; UPRI(V):400-230+/-15; USEC(V):2X115; ISEC(A):2X1,48; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|