промышленная комутационная техника
| Артикул |
Наименование |
Производитель |
|
4AM2696-2AA00-0NA0
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,033; UPRI(V):460; USEC(V):48; ISEC(A):0,687; F(HZ):60...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:70 /B; IP00; TYPE OF TERMINALS:FREE CONDUCTOR ENDS; INSTALLATION:SCREW; EN 61558-2-1>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-1CA00-0EA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,025; UPRI(V):230; USEC(V):23-21; ISEC(A):1,09; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-4 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EK80-0EA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,03; UPRI(V):440-415-380; USEC(V):24 (UO CA. 28,4V); ISEC(A):1,25; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6>UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK60-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,038; UPRI(V):115; USEC(V):15; ISEC(A):2,533; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK50-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,038; UPRI(V):120; USEC(V):15; ISEC(A):2,533; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EK48-0KB0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,025; UPRI(V):110; USEC(V):24; ISEC(A):1,042; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:MOUNTING RAILS; EN 61558-2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK48-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,025; UPRI(V):110; USEC(V):24; ISEC(A):1,04; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-6>UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK40-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,025; UPRI(V):110; USEC(V):24; ISEC(A):1,04; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:FREE CONDUCTOR ENDS; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK30-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,02 /0; UPRI(V):24; USEC(V):230; ISEC(A):0,087; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2>ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK20-0CS1
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,02 /0; UPRI(V):24; USEC(V):230; ISEC(A):0,087; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK10-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,025; UPRI(V):240; USEC(V):24; ISEC(A):1,04; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:FREE CONDUCTOR ENDS; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EK00-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,02 /0,052; UPRI(V):400-230; USEC(V):24; ISEC(A):0,83; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EJ80-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,025 /0,063; UPRI(V):230; USEC(V):24; ISEC(A):1,04; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ70-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,025 /0,063; UPRI(V):230; USEC(V):11; ISEC(A):2,27; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ70-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,025 /0,063; UPRI(V):230; USEC(V):11; ISEC(A):2,27; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EJ60-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,025 /0,063; UPRI(V):208+/-5%; USEC(V):230; ISEC(A):0,109; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EJ50-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,015 /0,048; UPRI(V):230; USEC(V):24; ISEC(A):0,63; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ50-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,015 /0,048; UPRI(V):230; USEC(V):24; ISEC(A):0,63; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ50-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,015 /0,048; UPRI(V):230; USEC(V):24; ISEC(A):0,63; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ40-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,02 /0,058; UPRI(V):230; USEC(V):24; ISEC(A):0,833; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ40-0EC0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,02 /0,058; UPRI(V):230; USEC(V):24; ISEC(A):0,833; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ40-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,02 /0,058; UPRI(V):230; USEC(V):24; ISEC(A):0,833; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EJ30-0EB0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,03; UPRI(V):277-230-115; USEC(V):24; ISEC(A):1,25; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:MOUNTING RAILS; EN 61558-2-1, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EJ10-1JC0
|
ISOLATION TRANSFORMER; PHASES:1; PN(KVA):0,025; UPRI(V):57; USEC(V):100, UO=113V; ISEC(A):0,25; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4>ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EJ00-0JA0
|
ISOLATION TRANSFORMER; PHASES:1; PN(KVA):0,02; UPRI(V):500-380+/-20V; USEC(V):125-110; ISEC(A):0,16-0,18; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-4>UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM2696-0EH80-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,018; UPRI(V):110; USEC(V):9; ISEC(A):2,0; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EH60-0KA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,04; UPRI(V):210; USEC(V):12; ISEC(A):3,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EH50-0AA0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,312; UPRI(V):235; USEC(V):208; ISEC(A):1,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13>UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EH40-0FS1
|
ISOLATION TRANSFORMER; PHASES:1; PN(KVA):0,01; UPRI(V):400; USEC(V):230; ISEC(A):0,043; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:60 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-4 >MAINS TRANSFORMER<>ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM2696-0EH30-1EA0
|
SAFETY ISOLATING TRANSFORMER; PHASES:1; PN(KVA):0,04; UPRI(V):500-480-460-440-415- 400; USEC(V):24; ISEC(A):1,67; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-6 >UL/CSA-RECOGNIZED<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
Товары
5971 - 6000 из 13660
Начало
|
Пред.
|
198
199
200
201
202
|
След. |