4AM3496-0AJ10-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,075 /0,211; UPRI(V):550-490-405-230-127-30- 20; USEC(V):24(PRIM. SPARANZ.230V /10VA); ISEC(A):0,05-3,125; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0/IA0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3496-0AH30-1NA0
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,075; UPRI(V):230+/-5%; USEC(V):30(2X15-12-10)JE2,5A GLEICHZEITIG; ISEC(A):JE2,5A GLEICHZEITIG; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /1; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM3496-0AE50-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,1 /0,312; UPRI(V):230(2X115); USEC(V):115; ISEC(A):0,87; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3496-0AE30-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):575; USEC(V):115; ISEC(A):0,870; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3496-0AE00-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,1 /0; UPRI(V):380+/-5%; USEC(V):28-24; ISEC(A):3,6-4,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-4 >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM3496-0AD70-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400+/-5%; USEC(V):230; 12; ISEC(A):0,43; 0,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3496-0AD70-0CA0
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,1 /0,312; UPRI(V):400+/-5%; USEC(V):230-12; ISEC(A):0,43-0,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3496-0AC60-0NA0
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,1; UPRI(V):230; USEC(V):230-200-170-140-110; ISEC(A):0,435-0,435-0,435- 0,435-0,435; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-4 >MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens)
|
Siemens
|
|
4AM3496-0AA80-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):230;230; USEC(V):115; ISEC(A):0,87; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1; -2-2; -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3495-6CA00-0NN2
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,1; UPRI(V):220(2X110); USEC(V):48(2X24); ISEC(A):2,1-4,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1>MAINS TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3495-2LA00-0NN2
|
Control circuit transformer; phases: 1; PN/PN (S6) (kVA): 0,1/0,304; UPRI (V): 440-380-220; Usec (V): 220 (2x 110); ISEC (A): 0,55-1,10; F (Hz): 50...60; vector GR./shield WNG.: II0/0; TA/ISO class: 50/B; IP00; type of terminals: screw/tab connection; installation: screws/mounting rails; EN 61558-2-1 >mains transformer < (siemens)
|
Siemens
|
|
4AM3495-0BN60-0C
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,1 /0,308; UPRI(V):400+/-5%; USEC(V):230 ; 24; ISEC(A):0,22 ; 2,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0I0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; VDE 0550 (siemens)
|
Siemens
|
|
4AM3495-0BJ20-0K
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):230-120; USEC(V):24; ISEC(A):4,167; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS VDE 0550 ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3495-0BE80-0NN2
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,1; UPRI(V):230-115; USEC(V):24; ISEC(A):4,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1>MAINS TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3495-0BE00-0NN2
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,1; UPRI(V):400-230; USEC(V):230; ISEC(A):0,435; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1>MAINS TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3495-0AP30-1NN2
|
MAINS TRANSFORMER; PHASES:1; PN(KVA):0,077; UPRI(V):230-208; USEC(V):22-15-8-8-15; ISEC(A):2,04-0,54-0,6-1,6-0,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIIIII0 /1; TA/ISOKL:70 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558>MAINS TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3495-0AE68-0NN2
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,05 /0,143; UPRI(V):500-460-415-380-227; USEC(V):24; ISEC(A):1,77; F(HZ):50...60; VECTOR GR./SHIELD WNG.:I I 0 /0; TA/ISOKL:66 /H; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:MOUNTING RAILS; 006902 BV01 (siemens)
|
Siemens
|
|
4AM3495-0AD80-0CN2
|
CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):0,065 /0,189; UPRI(V):460-440-415-400-380- 230-220; USEC(V):24-12 (55VA-10VA) GLEICHZEITIG; ISEC(A):2,708-2,708; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2 >CONTROL CIRCUIT TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3452-1TB50-0AD0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,32; UPRI(V):230; USEC(V):190-175-150-125-100-80; ISEC(A):1,68 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM3452-1TB50-0AC0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,36; UPRI(V):230; USEC(V):190-175-150-125-100-80; ISEC(A):1,9 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP23; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-13>UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM3452-1TB50-0AA0
|
AUTOTRANSFORMER; PHASES:1; PN,D(KVA):0,4; UPRI(V):230; USEC(V):190-175-150-125-100-80; ISEC(A):2,1 CONST.; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IA0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-13 >UL/CSA-RECOGNIZED< >AUTOTRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8MD40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):440-400-230; USEC(V):230(2X115); ISEC(A):0,435-0,870; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8MB40-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):440-400-230; USEC(V):48(2X24); ISEC(A):2,08-4,17; F(HZ):50...60; VECTOR GR./SHIELD WNG.:IIII0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8LT10-0FS1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230; USEC(V):230; ISEC(A):0,43; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-4 (siemens)
|
Siemens
|
|
4AM3442-8JX00-0FA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):48; ISEC(A):2,083; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JV00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):1,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JV00-0EA0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,1 /0,31; UPRI(V):400-230+/-15; USEC(V):42; ISEC(A):2,38; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0ED1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0ED0
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,08 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,33; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP54; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-6 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER<>SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|
|
4AM3442-8JN00-0EC1
|
TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,09 /0,31; UPRI(V):400-230+/-15; USEC(V):24; ISEC(A):3,75; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP23; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREWS/MOUNTING RAILS; EN 61558-2-1, -2-2, -2-6>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< >SAFETY ISOLATING TRANSFORMER< (siemens)
|
Siemens
|