Low-Voltage Power Distribution and Electrical Installation Technology (Низковольтная техника энергораспределения и электромонтажа)

Артикул Наименование Производитель
3VL7712-1BB46-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N NOT PROTECTED (siemens) Siemens
3VL7712-1TA46-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED (siemens) Siemens
3VL7712-1AK36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG RETURN APPLICATION WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens) Siemens
3VL7712-1AJ36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG RETURN APPLICATION WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT (siemens) Siemens
3VL7712-1SH36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens) Siemens
3VL7712-1SG36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens) Siemens
3VL7712-1SE36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens) Siemens
3VL7712-1AD36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG 3PHASES/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT (siemens) Siemens
3VL7712-1SL36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT (siemens) Siemens
3VL7712-1SB36-.... CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT (siemens) Siemens
3VL7712-1AA46-0AA0 CIRCUIT-BREAKER VL 1250N WITHOUT OVERCURRENT RELEASE STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE IN=< 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7712-1AA36-0AA0 CIRCUIT-BREAKER VL 1250N WITHOUT OVERCURRENT RELEASE STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE IN=< 1250A, RATED CURRENT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3UM36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3UL36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3UH36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3TE46-.... CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N UNPROTECTED (siemens) Siemens
3VL7710-3TB46-.... CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT (siemens) Siemens
3VL7710-3NN46-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3NH46-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3NF46-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3NB46-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3MH36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3MG36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3ML36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG 3PHASES/3WIRES IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3ME36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3MB36-0A.. CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1000A, RATED CURRENT IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL7710-3LA46-.... CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL7710-3LF46-.... CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL7710-3LE36-.... CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL7710-3LB36-.... CIRCUIT-BREAKER VL 1250L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1000A, RATED CURRENT IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens

Товары 3121 - 3150 из 5502
Начало | Пред. | 103 104 105 106 107 | След. | Конец Все