Low-Voltage Power Distribution and Electrical Installation Technology (Низковольтная техника энергораспределения и электромонтажа)
| Артикул |
Наименование |
Производитель |
|
3VL7712-1UL36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1UH36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1TE46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N UNPROTECTED (siemens)
|
Siemens
|
|
3VL7712-1TB46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL7712-1NN46-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1NH46-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1NF46-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1NB46-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1MH36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1MG36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1ML36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1ME36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1MB36-0A..
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL7712-1LA46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL7712-1LF46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL7712-1LE36-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL7712-1LB36-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1250A, RATED CURRENT IR= 500...1250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL7712-1EE46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, NON-AUTOMATIC OVERCURRENT RELEASE MAGNETIC IN=1250A, RATED CURRENT II=12000A, SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL7712-1DE36-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, NON-AUTOMATIC OVERCURRENT RELEASE MAGNETIC IN=1250A, RATED CURRENT II=12000A, SHORT-CIRCUIT II=12000A, SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL7712-1UN46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT (siemens)
|
Siemens
|
|
3VL7712-1UM36-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL7712-1UL36-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL7712-1UJ46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL7712-1UH36-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL7712-1TH46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL7712-1BG46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
|
3VL7712-1TF46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL7712-1BE46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD ISD=1,5TO9XIR, II=10XIN SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
|
3VL7712-1TN46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL7712-1BC46-....
|
CIRCUIT-BREAKER VL 1250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=1250A, RATED CURRENT IR=500-1250A, OVERLOAD II=1,25TO10XIN, SHORT CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
Товары
3091 - 3120 из 5502
Начало
|
Пред.
|
102
103
104
105
106
|
След. |
Конец
|