Building Automation Systems

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
3VL8716-3UM30-0A.. CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-3UL30-0A.. CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-3MH30-0A.. CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-3LF40-.... CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-3LE30-.... CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-3LB30-.... CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, II= 1.25 TO 9 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-3LA40-.... CIRCUIT-BREAKER VL 1600L VERY HIGH SWITCHING CAPACITY ICU= 100KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, II= 1.25 TO 9 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-2UM30-0A.. CIRCUIT-BREAKER VL 1600H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-2MH30-0A.. CIRCUIT-BREAKER VL 1600H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-2LF40-.... CIRCUIT-BREAKER VL 1600H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-2LE30-.... CIRCUIT-BREAKER VL 1600H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-2LB30-.... CIRCUIT-BREAKER VL 1600H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, II= 1.25 TO 9 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-2LA40-.... CIRCUIT-BREAKER VL 1600H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, II= 1.25 TO 9 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-1UM30-0A.. CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-1UL30-0A.. CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-1MH30-0A.. CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=1600A, RATED CURRENT IR=640-1600A, OVERLOAD ISD=1,5TO8XIR, II=9XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens) Siemens
3VL8716-1LF40-.... CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-1LE30-.... CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, ISD=1.5 TO 8 X IR, II=9 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-1LB30-.... CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, II= 1.25 TO 9 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8716-1LA40-.... CIRCUIT-BREAKER VL 1600N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 1600A, RATED CURRENT IR= 640...1600A, OVERLOAD PROTECTION, II= 1.25 TO 9 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens) Siemens
3VL8116-3KN30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3B160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 1600A, RATED CURRENT II= 7000...12000A SHORT-CIRCUIT PROTECTION IR= 1600A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3KE30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPS3S160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE SWITCH) OVERCURRENT RELEASE MAGNETIC TU= 40 DEGR. CELSIUS IN=< 1600A, RATED CURRENT II= 14000A SHORT-CIRCUIT PROTECTION ISOLATING CIRCUIT-BREAKER W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3JM30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3E160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3JH30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3D160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT ISD=1.25 TO 10 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3GH30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3U160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1600A, RATED CURRENT ISD=1.5 TO 8 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3GE30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3P160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT ISD=1.5 TO 8 X IR, II=6 X IN SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3GD30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3X160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 1600A, RATED CURRENT II= 1.25 TO 6 X IN, SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-3GB30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. LPX3N160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN= 1600A, RATED CURRENT II= 1.25 TO 6 X IN, SHORT-CIRCUIT PROTECTION IR= 700-1600A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-2KN30-.... CIRCUIT-BREAKER VL 1600 UL; TYPE PG (CAT NO. HPX3B160) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 1600A, RATED CURRENT II= 7000...12000A SHORT-CIRCUIT PROTECTION IR= 1600A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens) Siemens
3VL8116-2KE30-.... CIRCUIT BREAKER VL 1600 UL; TYPE PG (CAT NO. HPS3S160) NON-INTERCHANGEABLE FRAME W/APPROVAL CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE SWITCH) MAGNETIC OVERCURRENT TRIP UNIT TU= 40DEGR CELSIUS IN=< 1600A, RATED CURRENT II= 14000A SHORT-CIRCUIT PROTECTION NON-AUTOM. AIR CIRCUIT BR. W/O CONNECTION ACCESSORIES (siemens) Siemens

Òîâàðû 91 - 120 èç 3295
Íà÷àëî | Ïðåä. | 2 3 4 5 6 | Ñëåä. | Êîíåö Âñå