3VL9680-6UJ40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION LCD ETU40, LI/LS/LSI IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6UH30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION LCD ETU40, LI/LS/LSI IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6TH40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU22, LSIG IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6BG40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU22, LSIG IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6TF40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU20, LSI IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6TE40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU20, LSI IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6TN40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU12, LIG IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6BC40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU12, LIG IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6BB40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU10, LI IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6TA40
|
OVERCURRENT RELEASE VL 800 4 POLE, LINE PROTECTION ETU10, LI IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
|
3VL9680-6AS30
|
SCREWED UNION CONNECTIONS INCLUDED IN DELIVERY OF CONTACT UNIT RELEASE WITHOUT CONNECTIONS (siemens)
|
Siemens
|
|
3VL9680-6AK30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU22, LSIG RETURN APPLICATION WITH PIGTAIL IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6AJ30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU12, LIG RETURN APPLICATION WITH PIGTAIL IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT II=1,25TO11XIN, SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6SH30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU22, LSIG 3PHASE/4WIRE WITH PIGTAIL IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6SG30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU22, LSIG 3PHASE/3WIRE IR=320-800A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6SE30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU20, LSI IR=320-800A, OVERLOAD ISD=1,5TO7XIR, II=8XIN SHORT CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6AD30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU12, LIG 3PHASE/4WIRE WITH PIGTAIL IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6SL30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU12, LIG 3PHASE/3WIRE IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL9680-6SB30
|
OVERCURRENT RELEASE VL 800 3 POLE, LINE PROTECTION ETU10, LI IR=320-800A, OVERLOAD II=1,25TO8XIN, SHORT-CIRCUIT (siemens)
|
Siemens
|
|
3VL9675-4TF31
|
ACCESSORY FOR VL800XUL, (MG-FRAME) MULTIPLE LINE-SIDE TERMINAL FOR CU/AL FOR 2 CONDUCTORS PER TERMINAL 1SET = 3UNITS CAT NUMBER 3TA2MG750 BREAKER VL 3-LUG KIT CU-AL 2W 7 (siemens)
|
Siemens
|
|
3VL9675-4TF01
|
BREAKER VL LUG CU/AL 750KCMIL M CAT NUMBER TA2MG750 (siemens)
|
Siemens
|
|
3VL9670-7KN38
|
BREAKER VL CAT NMB. CMT3B700 3P 700A M-FR TM TU (siemens)
|
Siemens
|
|
3VL9670-7KN30
|
BREAKER VL 3P 700A M-FR TM TU CAT NMB. CMT3B700 3P 700A M-FR TM TU (siemens)
|
Siemens
|
|
3VL9670-7KN20
|
BREAKER VL 2P 700A M-FR TM TU CAT NMB. CMT2B700 2P 700A M-FR TM TU (siemens)
|
Siemens
|
|
3VL9660-8TT01
|
BREAKER VL NEUT CT 600A L/M CAT NUMBER NGSM600 (siemens)
|
Siemens
|
|
3VL9660-7KN30
|
VL MG 600 TMTU 3P CAT NMB. CMC3B600 3P 600A M-FR TM TU (siemens)
|
Siemens
|
|
3VL9660-7KN20
|
VL MG 600 TMTU 2P CAT NMB. CMT2B600 2P 600A M-FR TM TU (siemens)
|
Siemens
|
|
3VL9660-6JN41
|
OVERCURRENT RELEASE CMT5G600 4-POLE, PLANT PROTECTION, LIG/LSG/LSIG IR= 240...600 A, OVERLOAD PROTECTION, ISD=1.5 TO 7 X IR, II=8 X IN SHORT CIRCUIT PROTECTION, N PROTECTED WITH EARTH-FAULT PROTECTION (siemens)
|
Siemens
|
|
3VL9660-6JM31
|
OVERCURRENT RELEASE CMT3E600 3-POLE, PLANT PROTECTION, LIG/LSG/LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 240...600 A, OVERLOAD PROTECTION, ISD=1.5 TO 7 X IR, II=8 X IN SHORT CIRCUIT PROTECTION (siemens)
|
Siemens
|
|
3VL9660-6JJ41
|
OVERCURRENT RELEASE CMT5D600 4-POLE, PLANT PROTECTION, LI/LS/LSI IR= 240...600 A, OVERLOAD PROTECTION, ISD=1,5 TO 7 X IR, II=8 X IN SHORT CIRCUIT PROTECTION, N PROTECTED (siemens)
|
Siemens
|