3VL9710-6HF41 OVERCURRENT RELEASE CNT5P100 4-POLE, PLANT PROTECTION, LSI IR= 400...1000 A, OVERLOAD PROTECTION, ISD=1.5 TO 10X IR, II=11X IN SHORT CIRCUIT PROTECTION, N PROTECTED (siemens) Siemens
3VL9710-6HE41 OVERCURRENT RELEASE CNT4P100 4-POLE, PLANT PROTECTION, LSI IR= 400...1000 A, OVERLOAD PROTECTION, ISD=1.5 TO 10X IR, II=11X IN SHORT CIRCUIT PROTECTION, N UNPROTECTED (siemens) Siemens
3VL9710-6HD41 OVERCURRENT RELEASE CNT5X100 4-POLE, PLANT PROTECTION, LIG IR= 400...1000 A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT CIRCUIT PROTECTION, N PROTECTED (siemens) Siemens
3VL9710-6HC41 OVERCURRENT RELEASE CNT4X100 4-POLE, PLANT PROTECTION, LIG IR= 400...1000 A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT CIRCUIT PROTECTION, N UNPROTECTED (siemens) Siemens
3VL9710-6HB41 OVERCURRENT RELEASE CNT4N100 4-POLE, PLANT PROTECTION, LI IR= 400...1000 A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT CIRCUIT PROTECTION, N UNPROTECTED (siemens) Siemens
3VL9710-6HA41 OVERCURRENT RELEASE CNT5N100 4-POLE, PLANT PROTECTION, LI IR= 400...1000 A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT CIRCUIT PROTECTION, N PROTECTED (siemens) Siemens
3VL9710-6GH31 OVERCURRENT RELEASE CNT3U100 3-POLE, PLANT PROTECTION LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 400...1000 A, OVERLOAD PROTECTION, ISD=1.5 TO 10X IR, II=11X IN SHORT CIRCUIT PROTECTION (siemens) Siemens
3VL9710-6GG31 OVERCURRENT RELEASE CNT3R100 3-POLE, PLANT PROTECTION LSIG 3 PHASES/3 WIRES IR= 400...1000 A, OVERLOAD PROTECTION, ISD=1.5 TO 10X IR, II=11X IN SHORT CIRCUIT PROTECTION (siemens) Siemens
3VL9710-6GE31 Overcurrent release CNT3P100 3-pole, plant protection LSI IR=400...1000A, overload protection, ISD=1.5 to 10X IR, II=11X IN=8 short circuit protection (siemens) Siemens
3VL9710-6GD31 OVERCURRENT RELEASE CNT3X100 3-POLE, PLANT PROTECTION LIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 400...1000 A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT CIRCUIT PROTECTION (siemens) Siemens
3VL9710-6GC31 OVERCURRENT RELEASE CNT3V100 3-POLE, SYSTEM PROTECTION LIG 3 PHASES/3 CABLES IR= 400...1000A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT-CIRCUIT PROTECTION (siemens) Siemens
3VL9710-6GB31 OVERCURRENT RELEASE CNT3N100 3-POLE, PLANT PROTECTION LI IR= 400...1000 A, OVERLOAD PROTECTION, II= 1.25 TO 11X IN, SHORT CIRCUIT PROTECTION (siemens) Siemens
3VL9710-6JM30 PSU-ETU 3P 1000A (siemens) Siemens
3VL9710-6CP30 Overcurrent release VL 1250 3-pole, motor/generator LCD ETU40m, LI IR=400-1000A, overload ISD=1,5 to 10x IR, II=11x IN short circuit (siemens) Siemens
3VL9710-6UN40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION LCD ETU42, LSIG IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT (siemens) Siemens
3VL9710-6UM30 OVERCURRENT RELEASE VL 1250 3 POLE, LINE PROTECTION LCD ETU42, LSIG 3PHASE/4WIRE WITH PIGTAIL IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT CIRCUIT (siemens) Siemens
3VL9710-6UL30 OVERCURRENT RELEASE VL 1250 3 POLE, LINE PROTECTION LCD ETU42, LSIG 3PHASE/3WIRE IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT CIRCUIT (siemens) Siemens
3VL9710-6UJ40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION LCD ETU40, LI/LS/LSI IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED (siemens) Siemens
3VL9710-6UH30 OVERCURRENT RELEASE VL 1250 3 POLE, LINE PROTECTION LCD ETU40, LI/LS/LSI IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT CIRCUIT (siemens) Siemens
3VL9710-6TH40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU22, LSIG IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED (siemens) Siemens
3VL9710-6BG40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU22, LSIG IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED (siemens) Siemens
3VL9710-6TF40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU20, LSI IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED (siemens) Siemens
3VL9710-6TE40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU20, LSI IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED (siemens) Siemens
3VL9710-6TN40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU12, LIG IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED (siemens) Siemens
3VL9710-6BC40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU12, LIG IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N NOT PROTECTED (siemens) Siemens
3VL9710-6BB40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU10, LI IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N NOT PROTECTED (siemens) Siemens
3VL9710-6TA40 OVERCURRENT RELEASE VL 1250 4 POLE, LINE PROTECTION ETU10, LI IR=400-1000A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED (siemens) Siemens
3VL9816-6AS30 SCREWED UNION CONNECTIONS INCLUDED IN DELIVERY OF CONTACT UNIT (siemens) Siemens
3VL9710-6AP30 Overcurrent release VL 1250 3-pole, motor/generator ETU10m, LI protection IR=400-1000A, overload II=1,25 to 11x IN, short-circuit (siemens) Siemens
3VL9710-6AK30 OVERCURRENT RELEASE VL 1250 3 POLE, LINE PROTECTION ETU22, LSIG RETURN APPLICATION WITH PIGTAIL IR=400-1000A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT CIRCUIT (siemens) Siemens