Building Automation Systems
| Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
|
3VL2716-2LE33-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LE33-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LB36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LB36-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LB33-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LB33-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LA46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LA46-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. SCREW TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LA43-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2LA43-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 160A, RATED CURRENT IR= 64...160A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
|
3VL2716-2CP36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, MOTOR/GENERATOR PROTECTION OVERCURRENT RELEASE LCD ETU40M, LI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CN46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CN46-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SCREW CONNECTION (siemens)
|
Siemens
|
|
3VL2716-2CN43-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CM36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CM36-....
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
|
3VL2716-2CM33-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CL36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CJ46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2CH36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BH46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BG46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BF46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BE46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU20, LSI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BD46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BC46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2BB46-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU10, LI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2AS33-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IN=160A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2AP36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, MOTOR/ GENERATOR PROTECTION OVERCURRENT RELEASE ETU10M, LI IN=160A, RATED CURRENT IR=64-160A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
|
3VL2716-2AK36-0A..
|
CIRCUIT-BREAKER VL 160H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG RETURN APPLICATION WITH PIGTAIL IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
Òîâàðû
1381 - 1410 èç 3295
Íà÷àëî
|
Ïðåä.
|
45
46
47
48
49
|
Ñëåä. |