| | DIGITAL MONITORING RELAY SPEED MONITORING, FOR IO-LINK FROM 0.1 TO 2200 RPM OVERSHOOT AND UNDERSHOOT ON DELAY TIME TRIPPING DELAY TIME HYSTERESIS 0.1 TO 99 RPM 1 CHANGE-OVER CONTACT, SCREW TERMINAL |
| Product function | | RPM monitoring relay |
| |
| Measuring circuit: | | |
| Adjustable response delay time | | |
| | s | 0… 999.9 |
- with lower or upper limit violation
| s | 0… 999.9 |
| Adjustable response value revolution | 1/min | 0… 2,200 |
| Input voltage / at the digital input 1 | | |
- initial value for signal<0>-recognition
| V | 0 |
- final value for signal<0>-recognition
| V | 1 |
- initial value for signal<1>-recognition
| V | 4.5 |
- final value for signal<1>-recognition
| V | 30 |
| Input current / at the digital input 2 | | |
- initial value for signal<0>-recognition
| mA | 0 |
- final value for signal<0>-recognition
| mA | 1.2 |
- initial value for signal<1>-recognition
| mA | 2.1 |
- final value for signal<1>-recognition
| mA | 8.2 |
| Design of the input / reducing-entrance | | No |
| Design of the sensor | | |
- at the digital input 1 / connectable
| | PNP switching three-wire sensor or mechanical impulse contact with external DC supply (4.5 V … 30 V) |
- at the digital input 2 / connectable
| | 2-conductor Namur sensor or mechanical impulse contact |
| Input current / at the digital input 1 / maximum | mA | 50 |
| Pulse duration | ms | 5 |
| Pulse interval | ms | 5 |
| Number of sensor signals per revolution | | 1… 10 |
| Switching hysteresis for rotational speed | 1/min | 0… 99.9 |
| |
| General technical details: |
| Design of the display | | LCD |
| Product function | | |
- rotation speed monitoring
| | Yes |
| | | No |
| | | Yes |
| | | Yes |
| | | Yes |
| | | Yes |
- open-circuit or closed-circuit current principle
| | Yes |
| Starting time / after the control supply voltage has been applied | ms | 500 |
| Response time / maximum | ms | 100 |
| Relative metering precision | % | 10 |
| Precision of digital display | | +/- 1 Digit |
| Relative repeat accuracy | % | 1 |
| Type of voltage / of the controlled supply voltage | | DC |
| Control supply voltage | | |
| | | |
| | V | 24… 24 |
| Working range factor supply voltage rated value | | |
| | | 0.75… 1.25 |
| Impulse voltage resistance / rated value | kV | 4 |
| Recorded real power | W | 2 |
| Protection class IP | | IP20 |
| Electromagnetic compatibility | | IEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4 |
| Resistance against vibration / according to IEC 60068-2-6 | | 1 … 6 Hz: 15 mm, 6 … 500 Hz: 2g |
| Resistance against shock / according to IEC 60068-2-27 | | sinusoidal half-wave 15g / 11 ms |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV |
| Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
| Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
| Electrostatic discharge / according to IEC 61000-4-2 | | 6 kV contact discharge / 8 kV air discharge |
| Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
| Degree of pollution | | 2 |
| Apparent power consumed | | |
- at 24 V / for DC / maximum
| V·A | 4 |
| Ambient temperature | | |
| | °C | -25… +60 |
| | °C | -40… +80 |
| | °C | -40… +80 |
| Galvanic isolation | | |
- between entrance and outlet
| | Yes |
| | | No |
- between the voltage supply and other circuits
| | Yes |
| Acceptability for application / safety-related circuits | | No |
| Category / according to EN 954-1 | | none |
| safety Integrated Level / according to IEC 61508 | | none |
| |
| Communication: | | |
| Type of voltage supply / via input/ output link master | | Yes |
| IO-Link transfer rate | | COM2 (38,4 kBaud) |
| Protocol / will be supported / IO-Link protocol | | Yes |
| Data volume | | |
- of the address range of the outputs / with cyclical transfer
| byte | 2 |
- of the address range of the inputs / with cyclical transfer
| byte | 4 |
| Point-to-point cycle time / between master and IO-Link device / minimum | ms | 10 |
| |