| | BASIC UNIT 2 SIMOCODE PRO V; PROFIBUS DP INTERFACE 12 MBIT/S, RS485; 4I/3O FREELY PARAMETERIZABLE; US: DC 24V; THERMISTOR MOTOR PROTECTION; RELAY OUTPUTS MONOSTABLE; EXPANDABLE BY EXPANSION MODULES |
| |
| General technical data: |
| product brand name | | SIRIUS |
| Protection class IP | | IP20 |
| Built in orientation | | any |
| EMC immunity to interference / according to IEC 60947-1 | | corresponds to degree of severity 3 |
| Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV (power ports) / 1 kV (signal ports) |
| Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
| Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
| Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
| EMC emitted interference / according to IEC 60947-1 | | class A |
| Resistance against vibration | | 1-6 Hz / 15 mm; 6-500 Hz / 2 g |
| Impulse voltage resistance / rated value | V | 4,000 |
| Insulation voltage / rated value | V | 300 |
| Active power loss / total / typical | W | 7 |
| Switching behaviour | | monostable |
| Number of outputs | | 3 |
| Number of inputs | | 4 |
| Number of semiconductor outputs | | 0 |
| Number of outputs / as contact-affected switching element | | 3 |
| Product component | | |
- input for thermistor connection
| | Yes |
- input for analog temperature sensors
| | No |
- input for ground-fault detection
| | No |
| Product function | | |
| | | Yes |
| | | Yes |
| Item designation | | |
- according to DIN EN 61346-2
| | F |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | F |
| |
| Communication: |
| Product function | | |
| | | Yes |
| Protocol / will be supported / PROFIBUS DP protocol | | Yes |
| |
| Main circuit: |
| Operating voltage | | |
| | V | 24… 24 |
| |
| Supply voltage: |
| Type of voltage | | |
| | | DC |
| |
| Control circuit: |
| Type of voltage | | |
- of the controlled supply voltage
| | DC |
| Control supply voltage | | |
| | V | 24 |
| | V | 24… 24 |
| |
| Installation/mounting/dimensions: |
| Type of mounting | | screw and snap-on mounting |
| Width | mm | 45 |
| Height | mm | 111 |
| Depth | mm | 124 |
| |
| Connections: |
| Product function | | |
- removable terminal for auxiliary and control circuit
| | Yes |
| Design of the electrical connection | | |
- for auxiliary and control current circuit
| | screw-type terminals |
| Conductor cross-section that can be connected / for auxiliary contact | | |
| | mm² | 0.5… 4 |
| | | |
- with conductor end processing
| mm² | 0.5… 2.5 |
- without conductor final cutting
| mm² | 0.5… 2.5 |
| AWG number / as coded connectable conductor cross-section | | |
| | | 20… 14 |
| |
| Ambient conditions: |
| Installation altitude / at a height over sea level / maximum | m | 4,000 |
| Ambient temperature | | |
| | °C | -40… +80 |
| | °C | -25… +60 |
| | °C | -40… +80 |
| Relative humidity / during operating phase | % | 5… 95 |
| |
| Certificates/approvals: |
| Verification of suitability | | CE / UL / CSA / CCC / C-TICK / GOST / NOM / ATEX / NEPSI / ABS / DNV / GL / LRS / RoHS |
| General Product Approval | For use in hazardous locations | | | |
| | |
| |
| last change: | Mar 12, 2012 |