| | SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCK. FORCE 2600N;5 APPR. DIR. METAL HOUSING,3X(M20X1.5) SPRING-LOCKED, AUXILIARY RELEASE W. LOCK MAGNET VOLTAGE 230V AC, MONITOR. OF ACTUATOR 2NC/1NO, MONITOR. OF MAGNET 2NC/1NO LEDS YELLOW/GREEN |
| |
| General technical details: | | |
| Supply voltage | | |
| | V | 230 |
| Type of voltage / of the supply voltage | | |
- of the optional LED display
| | AC |
| Relative ON period | | |
| | % | 100 |
| Recorded real power | | |
| | W | 3.5 |
| Insulation voltage | | |
| | V | 250 |
| Degree of pollution | | class 3 |
| Thermal current | A | 6 |
| Operating current | | |
| | | |
| | A | 6 |
| | A | 3 |
| | A | 1.5 |
| | | |
| | A | 3 |
| | A | 0.55 |
| | A | 0.27 |
| Continuous current | | |
- of the slow DIAZED fuse link
| A | 6 |
- of the quick DIAZED fuse link
| A | 10 |
- of the C characteristic circuit breaker
| A | 0.5 |
| Mechanical operating cycles as operating time / typical | | 1,000,000 |
| Electrical operating cycles as operating time | | |
- with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026 / typical
| | 1,000,000 |
| Electrical operating cycles in one hour | | |
- with contactor 3RH11, 3RT1016, 3RT1017, 3RT1024, 3RT1025, 3RT1026
| | 6,000 |
| Repeat accuracy | mm | 0.05 |
| Design of the contact element | | slow-action contacts |
| Number of NC contacts | | |
- for the position surveillance of the locking element
| | 2 |
| Number of NC contacts | | |
- for the position surveillance of the activation element
| | 2 |
| Number of NO contacts | | |
- for the position surveillance of the locking element
| | 1 |
| Number of NO contacts | | |
- for the position surveillance of the activation element
| | 1 |
| Design of the switching function | | positive opening |
| Resistance against vibration | | 0.35 mm / 5g |
| Resistance against shock | | 30g / 11 ms |
| Ambient temperature | | |
| | °C | -25… +60 |
| | °C | -40… +80 |
| Width of the sensor | mm | 54 |
| material | | |
| | | metal |
| Material / of the housing / of the switch head | | metal |
| Design of the operating mechanism | | 5 directions of approach |
| Actuating speed | m/s | 0.4… 1.5 |
| Minimum actuating force | N | 30 |
| Protection class IP | | IP66/IP67 |
| Built in orientation | | any |
| Cable gland version | | 3 x (M20 x 1.5) |
| Design of the electrical connection | | screw-type terminals |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | S |
- according to DIN EN 61346-2
| | B |
| |
| Certificates/approvals: | | |
| General Product Approval | Functional Safety / Safety of Machinery | | | |
| | |
| | |
| |
| last change: | Feb 27, 2012 |