| | MOLDED CASE CIRC.BREAKER 3RV1 FOR STARTER COMBINATION STANDARD SWITCHING CAPACITY RATED CURRENT IN=32A MAGNETIC RELEASE SHORT-CIRCUIT PROTECTION ADJUSTABLE 6-13XLN ICU =85KA AT 400V 3-POLE, SCREW TERMINAL INCL. PHASE BARRIERS |
| |
| General technical data: |
| product brand name | | SIRIUS |
| product designation | | molded-case circuit breaker |
| Size of the circuit-breaker | | 3RV1.5 |
| Degree of pollution | | 3 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Protection class IP / on the front | | IP20 |
| Ambient temperature | | |
| | °C | -40… +70 |
| | °C | -25… +70 |
| | °C | 70… -40 |
| Resistance against shock | | 25g / 11 ms |
| Insulation voltage / rated value | V | 800 |
| Impulse voltage resistance / rated value | V | 8,000 |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | Q |
- according to DIN EN 61346-2
| | Q |
| Mechanical operating cycles as operating time / of the main contacts / typical | | 25,000 |
| Type of the driving mechanism / motor drive | | No |
| Design of the operating mechanism | | toggle handle |
| Product function | | |
| | | No |
- phase disturbance recognition
| | No |
| Product component | | |
| | | No |
- undervoltage release mechanism
| | No |
| | | No |
| Product extension / optional / motor drive | | No |
| |
| Main circuit: |
| Number of poles / for main current circuit | | 3 |
| type of voltage | | AC |
| Operating voltage / at AC-3 / rated value / maximum | V | 690 |
| Operating current / at AC-3 / at 400 V / rated value | A | 32 |
| Service power / at AC-3 | | |
| | kW | 15 |
| Frequency of operation / at AC-3 / according to IEC 60947-6-2 / maximum | 1/h | 15 |
| Arrangement of electrical connectors / for main current circuit | | front side |
| Adjustable response current | | |
- of the non-delayed short-circuit release
| A | 192… 384 |
| Continuous current / rated value | A | 32 |
| Product extension / auxiliary switch | | Yes |
| |
| Auxiliary circuit: |
| Number of NC contacts / for auxiliary contacts / instantaneous switching | | 0 |
| Number of NO contacts / for auxiliary contacts / instantaneous switching | | 0 |
| Number of change-over switches / for auxiliary contacts | | 0 |
| |
| Inputs/ Outputs: | | |
| Number of digital inputs | | 0 |
| |
| Short-circuit: |
| Breaking capacity limit short-circuit current (lcu) | | |
| | kA | 85 |
| | kA | 50 |
| | kA | 10 |
| Design of the electrical connection / for auxiliary and control current circuit | | screw-type terminals |
| Design of the overcurrent release and short-circuit release | | magnetic |
| |
| Installation/mounting/dimensions: |
| Built in orientation | | any |
| Type of mounting | | screw fixing |
| Width | mm | 90 |
| Height | mm | 130 |
| Depth | mm | 70 |
| Distance, to be maintained, to the ranks assembly | | |
| | mm | 0 |
| | mm | 0 |
| Product function / removable terminal for auxiliary and control circuit | | No |
| |
| Connections: |
| Design of the electrical connection | | |
| | | screw-type terminals |
| |
| Certificates/approvals: | | |
| General Product Approval | Test Certificates | Shipping Approval | | ROSTEST | Manufacturer | | | Manufacturer | other | | | | | |
| |
| Safety: | | |
| Protection against electrical shock | | finger-safe |
| |
| Further information: |
| Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs |
| Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall |
| CAx-Online-Generator http://www.siemens.com/cax |
| Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RV1353-6MM10/all |
| Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RV1353-6MM10 |
| |
| |
| | |
| |
| last change: | Feb 27, 2012 |