| | CIRCUIT-BREAKER, SIZE S3, FOR MOTOR PROTECTION, CLASS 10, A-RES. 36...50 A, N-RES. 650 A, 1 NO + 1 NC TRANSVERSE, SCREW CONNECTION, STANDARD SWITCHING CAPACITY |
| |
| General technical data: |
| product brand name | | SIRIUS |
| product designation | | circuit breaker |
| Size of the circuit-breaker | | S3 |
| Trip class | | CLASS 10 |
| Degree of pollution | | 3 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Protection class IP / on the front | | IP20 |
| Ambient temperature | | |
| | °C | -50… 80 |
| | °C | -20… 70 |
| | °C | 80… -50 |
| Resistance against shock | | 25g / 11 ms |
| Insulation voltage / rated value | V | 690 |
| Impulse voltage resistance / rated value | V | 6,000 |
| Active power loss / total / typical | W | 20 |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | Q |
- according to DIN EN 61346-2
| | Q |
| Mechanical operating cycles as operating time / of the main contacts / typical | | 50,000 |
| Design of the auxiliary switch | | transverse |
| Type of the driving mechanism / motor drive | | No |
| Design of the operating mechanism | | selector switch |
| Product function | | |
| | | Yes |
- phase disturbance recognition
| | Yes |
| Product component | | |
| | | Yes |
- undervoltage release mechanism
| | No |
| | | Yes |
| Product extension / optional / motor drive | | Yes |
| |
| Main circuit: |
| Number of poles / for main current circuit | | 3 |
| type of voltage | | AC/DC |
| Operating voltage / at AC-3 / rated value / maximum | V | 690 |
| Operating current / at AC-3 / at 400 V / rated value | A | 50 |
| Service power / at AC-3 | | |
| | kW | 22 |
| Frequency of operation / at AC-3 / according to IEC 60947-6-2 / maximum | 1/h | 15 |
| Arrangement of electrical connectors / for main current circuit | | front side |
| Adjustable response current | | |
- of the non-delayed short-circuit release
| A | 650… 650 |
| Adjustable response current | | |
- of the current-dependent overload release
| A | 36… 50 |
| Continuous current / rated value | A | 50 |
| Product extension / auxiliary switch | | Yes |
| |
| Auxiliary circuit: |
| Number of NC contacts / for auxiliary contacts / instantaneous switching | | 1 |
| Number of NO contacts / for auxiliary contacts / instantaneous switching | | 1 |
| Number of change-over switches / for auxiliary contacts | | 0 |
| Operating current / of the auxiliary contacts | | |
| | | |
| | A | 2 |
| | A | 0.5 |
| | | |
| | A | 1 |
| | A | 0.15 |
| |
| Inputs/ Outputs: | | |
| Number of digital outputs | | 0 |
| |
| Short-circuit: |
| Breaking capacity limit short-circuit current (lcu) | | |
| | kA | 50 |
| | kA | 12 |
| | kA | 6 |
| Design of the electrical connection / for auxiliary and control current circuit | | screw-type terminals |
| Design of the overcurrent release and short-circuit release | | thermomagnetic |
| |
| Installation/mounting/dimensions: |
| Built in orientation | | any |
| Type of mounting | | screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 |
| Width | mm | 70 |
| Height | mm | 165 |
| Depth | mm | 174 |
| Distance, to be maintained, to the ranks assembly | | |
| | mm | 0 |
| | mm | 0 |
| Product function / removable terminal for auxiliary and control circuit | | No |
| |
| Connections: |
| Design of the electrical connection | | |
| | | screw-type terminals with box terminals |
| Type of the connectable conductor cross-section | | |
| | | |
| | | 2x (2.5 ... 16 mm2) |
| | | 2x (10 ... 50 mm2), 10 ... 70 mm2 |
| | | |
- with conductor end processing
| | 2x (2.5 ... 35 mm2), 2.5 ... 50 mm2 |
| | | |
| | | 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2) |
- finely stranded / with conductor end processing
| | 2x (0.5 ... 1.5 mm2), 2x (0.75 ... 2.5 mm2) |
- for AWG conductors / for auxiliary contacts
| | 2x (18 ... 14) |
| Conductor cross section that can be connected / for main contacts | | |