| | TIME RELAY, STAR-DELTA SINGLE TIME RANGE 20 S AC 24 V DC 200...240 V 0.7...1.25 US REUSABLE PACKING PACKING = 192 ITEMS |
| |
| General technical details: |
| product brand name | | SIRIUS |
| product designation | | timing relay |
| Protection class IP / on the front | | IP40 |
| Protection class IP / of the terminal | | IP20 |
| Built in orientation | | any |
| Supply voltage frequency | | |
- 1 / for auxiliary and control current circuit
| | |
| | Hz | 50 |
| | Hz | 60 |
| Product function | | |
| | | Yes |
- with auxiliary voltage / pulse-shaping
| | No |
- at the relay outputs / changeover delayed/without delay
| | No |
| Product component / semi-conductor output | | No |
| Product extension / optional / remote control | | No |
| Product extension / strictly required / remote control | | No |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Ambient temperature | | |
| | °C | -40… +85 |
| | °C | -25… +60 |
| | °C | -40… +85 |
| Relative humidity | | |
| | % | 15… 70 |
| Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV network connection / 1 kV control connection |
| Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
| Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
| Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
| Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
| Resistance against vibration | | 10 ... 55 Hz / 0.35 mm |
| Impulse voltage resistance / rated value | V | 4,000 |
| Insulation voltage / rated value | V | 300 |
| Active power loss / total / typical | W | 2 |
| Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 | | K |
| Item designation / according to DIN EN 61346-2 | | K |
| Category / according to EN 954-1 | | none |
| Protection against electrical shock | | finger-safe |
| |
| Switching Function: | | |
| Switching function | | |
| | | No |
| | | No |
- firmly clocked beginning with pulse
| | No |
- firmly clocked beginning with pause
| | No |
| | | No |
- variably clocked start with impulse
| | No |
- impuls variably clocked start with pause
| | No |
| | | |
- in an additive way slow-operating
| | No |
| | | No |
| | | No |
- without auxiliary voltage / relapse delayed
| | No |
- slow-operating/instantaneous contact
| | No |
| | | |
- relapse delayed/instantaneous contact
| | No |
- slow-operating/relapse delayed/instantaneous contact
| | No |
- firmly clocked beginning with pause/instantaneous contact
| | No |
- making pulse contact/instantaneous contact
| | No |
| | | |
- temporary line fault/instantaneous contact
| | No |
- pulse modelling/instantaneous contact
| | No |
- slow-operating/instantaneous contact
| | No |
| |
| General details: |
| Type of voltage / of the controlled supply voltage | | AC/DC |
| Control supply voltage frequency | | |
| | Hz | 50… 60 |
| Control supply voltage | | |
| | | |
- at 50 Hz / for AC / rated value
| V | 24 |
- at 60 Hz / for AC / rated value
| V | 24 |
| | V | 24 |
| | | |
| | | |
| | V | 200… 240 |
| | | |
| | V | 200… 240 |
| Working range factor supply voltage rated value | | |
| | | |
| | | 0.85… 1.1 |
| | | |
| | | 0.85… 1.1 |
| | | 0.85… 1.1 |
| |
| Auxiliary circuit: | | |
| Operating current / of auxiliary contacts | | |
- as normally closed contact / for AC-15
| | |
| |