| TIMING RELAY, CONFIG. ON-DELAY 1 CO,5 TIME SETT.RANGES 15-100S 24 AC,200...240 V AND 24 V DC, WITH 2 LEDS, SPRING-LOADED TERMINAL |
|
General technical details: |
product brand name | | SIRIUS |
product designation | | timing relay |
Protection class IP / on the front | | IP40 |
Protection class IP / of the terminal | | IP20 |
Built in orientation | | any |
Supply voltage frequency | | |
- 1 / for auxiliary and control current circuit
| | |
| Hz | 50 |
| Hz | 60 |
Product function | | |
| | No |
- with auxiliary voltage / pulse-shaping
| | No |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -40… +85 |
| °C | -25… +60 |
| °C | -40… +85 |
Relative humidity | | |
| % | 15… 70 |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV network connection / 1 kV control connection |
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
Resistance against vibration | | 10 ... 55 Hz / 0.35 mm |
Impulse voltage resistance / rated value | V | 4,000 |
Insulation voltage / rated value | V | 300 |
Active power loss / total / typical | W | 2 |
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 | | K |
Item designation / according to DIN EN 61346-2 | | K |
Category / according to EN 954-1 | | none |
Protection against electrical shock | | finger-safe |
|
|
General details: |
Control supply voltage frequency | | |
| Hz | 50… 60 |
Control supply voltage | | |
| | |
- at 50 Hz / for AC / rated value
| V | 24 |
- at 60 Hz / for AC / rated value
| V | 24 |
| V | 24 |
| | |
| | |
| V | 200… 240 |
| | |
| V | 200… 240 |
Working range factor supply voltage rated value | | |
| | |
| | 0.85… 1.1 |
| | |
| | 0.85… 1.1 |
| | 0.85… 1.1 |
|
Auxiliary circuit: | | |
Operating current / of auxiliary contacts | | |
- as normally closed contact / for AC-15
| | |
| A | 3 |
| A | 3 |
- as normally open contact / for AC-15
| | |
| A | 3 |
| A | 3 |
| | |
| A | 3 |
| | |
| A | 1 |
| A | 0.2 |
| A | 0.1 |
Number of NC contacts / delayed switching | | 0 |
Number of NC contacts / non-delayed | | 0 |
|
Short-circuit: | | |
Design of the fuse link / for short-circuit protection of the auxiliary switch / required | | fuse gL/gG: 4 A |
Type of mounting | | screw and snap-on mounting onto 35 mm standard mounting rail |
|
Installation/mounting/dimensions: |
Width | mm | 22.5 |
Height | mm | 84 |
Depth | mm | 91 |
Distance, to be maintained, to the ranks assembly | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Distance, to be maintained, to earthed part | | |
| mm | 0 |
| mm | 0 |
| mm |
|