| | SIRIUS MOTOR STARTER M200D TECHNOLOGIEMODUL REVERSING STARTER ELECTRONIC SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTRONIC OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 4DI / 2DO HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH USING A COMMUNICATION MODULE 3RK1305* USABLE WITH PROFIBUS OR PROFINET |
| |
| General technical data: |
| product brand name | | SIRIUS |
| product designation | | motor starter module M200D |
| Design of the product | | reversing starter |
| Product function | | |
| | | No |
| | | Yes |
| | | Yes |
| | | Yes |
| Design of the switching contact | | solid-state / thyristor / 2 phases |
| Product component / outlet for enine brake | | No |
| Trip class | | CLASS 5, 10, 15, 20 |
| Type of assignement | | 1 |
| Product equipment | | |
- brake control with 230 V AC
| | No |
- brake control with 400 V AC
| | No |
- brake control with 24 V DC
| | No |
- brake control with 180 V DC
| | No |
- brake control with 500 V DC
| | No |
| Product extension / braking module for brake control | | No |
| Impulse voltage resistance / rated value | V | 6,000 |
| Start-up delay time | ms | 25 |
| Switch-off delay time | ms | 35 |
| Insulation voltage / rated value | V | 500 |
| Active power loss / typical | W | 30 |
| Maximum permissible voltage for safe disconnection | | |
- between main circuit and auxiliary circuit
| V | 400 |
- between control and auxiliary circuit
| V | 24 |
| Item designation | | |
- according to DIN EN 61346-2
| | Q |
| Type of mounting | | screw fixing |
| Width | mm | 294 |
| Height | mm | 215 |
| Depth | mm | 148 |
| |
| Main circuit: |
| Operating voltage | | |
| | V | 360… 440 |
| Adjustable response current | | |
- of the current-dependent overload release
| A | 0.15… 2 |
| Operating current / at AC-3 / at 400 V | | |
| | A | 2 |
| Service power / for three-phase servomotors / at 400 V / at 50 Hz | | |
| | kW | 0.06… 0.75 |
| Service power / at AC-3 | | |
| | kW | 0.75 |
| | W | 750 |
| Number of poles / for main current circuit | | 3 |
| Design of the short-circuit protection | | circuit-breakers |
| Breaking capacity limit short-circuit current (lcu) | | |
| | A | 50,000 |
| | A | 20,000 |
| Type of the motor protection | | full motor protection |
| |
| Control circuit: |
| Type of voltage / of the controlled supply voltage | | DC |
| Control supply voltage / 1 / for DC / rated value / permissible minimum | V | 20.4 |
| Control supply voltage / 1 / for DC / rated value / permissible maximum | V | 28.8 |
| Design of the electrical connection / for auxiliary and control current circuit | | connector |
| |
| Supply voltage: |
| Type of voltage / of supply voltage | | DC |
| |
| Ambient conditions: |
| Protection class IP | | IP65 |
| Ambient temperature | | |
| | °C | -40… +70 |
| | °C | -25… +55 |
| | °C | -40… +70 |
| Relative humidity | | |
| | % | 10… 95 |
| Resistance against vibration | | 7 mm / 2g |
| Resistance against shock | | 12g / 11 ms |
| Degree of pollution | | 3 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Built in orientation | | vertical, horizontal, flat |
| Built in orientation / recommended | | horizontal |
| |
| Communication: |
| Design of the interface | | |
| | | No |
| Protocol / will be supported | | |
| | | No |
| Design of the interface | | |
| | | No |
| Protocol / will be supported | | |
| | | No |
| Product function | | |
- control circuit interface with IO link
| | No |
- control circuit interface to parallel wiring
| | No |
| Design of the interface | | |
| | | No |
| Protocol / will be supported | | |
| | | No |
| |
| Connections: |
| Number of digital inputs | | 4 |
| Number of digital outputs | | 2 |
| Number of sockets | | |
- for digital input signals
| | 4
|