| | F-RS1E-X FOR ET 200S FAILSAFE REVERSING STARTER SETTING RANGE 2.4...8A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE |
| |
| General technical data: |
| product brand name | | Sirius |
| product designation | | motor starter ET 200S |
| Design of the product | | reversing starter |
| Product function | | |
| | | Yes |
| | | No |
| | | Yes |
| | | Yes |
| | | Yes |
| Design of the switching contact | | electromechanical |
| Product component / outlet for enine brake | | Yes |
| Trip class | | CLASS 10 and 20 adjustable |
| Type of assignement | | 2 |
| Product equipment | | |
- brake control with 230 V AC
| | No |
- brake control with 24 V DC
| | No |
- brake control with 180 V DC
| | No |
- brake control with 500 V DC
| | No |
| Product extension / braking module for brake control | | Yes |
| Impulse voltage resistance / rated value | kV | 6 |
| Insulation voltage / rated value | V | 500 |
| Active power loss / typical | W | 10 |
| Maximum permissible voltage for safe disconnection / between main circuit and auxiliary circuit | V | 400 |
| Item designation | | |
- according to DIN EN 61346-2
| | Q |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | A |
| Type of mounting | | Can be plugged into terminal module |
| Depth | mm | 150 |
| Height | mm | 290 |
| Width | mm | 130 |
| |
| Main circuit: |
| Operating voltage | | |
| | V | 400… 500 |
| Adjustable response current | | |
- of the current-dependent overload release
| A | 2.4… 8 |
| Service power | | |
- at AC-3 / at 400 V / rated value
| kW | 3 |
- for three-phase servomotors / at 400 V / at 50 Hz
| | |
| | kW | 1.1… 3 |
| Breaking capacity limit short-circuit current (lcu) / at 400 V / rated value | kA | 50 |
| Design of the short-circuit protection | | circuit-breakers |
| Number of poles / for main current circuit | | 3 |
| Type of the motor protection | | solid-state |
| Mechanical operating cycles as operating time / of the main contacts / typical | | 100,000 |
| |
| Control circuit: |
| Type of voltage / of the controlled supply voltage | | DC |
| Control supply voltage / 1 | | |
| | V | 24… 24 |
| Control supply voltage / 1 / for DC | | |
| | V | 21.6… 26.4 |
| |
| Supply voltage: | | |
| Type of voltage / of supply voltage | | DC |
| Supply voltage / 1 | | |
| | V | 24… 24 |
| Supply voltage / 1 / for DC | | |
| | V | 20.4… 28.8 |
| |
| Ambient conditions: |
| Protection class IP | | IP20 |
| Ambient temperature | | |
| | °C | 0… 60 |
| | °C | -40… +70 |
| | °C | -40… +70 |
| Relative humidity | | |
| | % | 5… 95 |
| Resistance against vibration | | 2g |
| Resistance against shock | | 5g / 11 ms |
| Degree of pollution | | 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131) |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Built in orientation | | vertical, horizontal |
| |
| Communication: | | |
| Protocol / will be supported | | |
| | | Yes |
| | | Yes |
| | | No |
| Design of the interface / PROFINET protocol | | Yes |
| Design of the electrical connection | | |
- of the communication interface
| | via backplane bus |
- for communication transmission
| | via backplane bus |
| |
| Connections: | | |
| Number of digital inputs | | 2 |
| Number of sockets | | |
- for digital input signals
| | 0 |
- for digital output signals
| | 0 |
| Product function | | |
- digital inputs parameterizable
| | Yes |
- digital outputs parameterizable
| | No |
| Design of the electrical connection | | |
- 1 / for digital input signals
| | using control module |
- 2 / for digital input signals
| | using control module |
- at the manufacturer-specific device interface
| | |