| | CONTACTOR RELAY, 2NO+2NC, AC 230V, 50/60 HZ, SIZE S00, SCREW TERMINAL, REUSABLE PACKAGE = 144 UNITS |
| |
| General technical data: |
| product brand name | | SIRIUS |
| Size of the contactor | | S00 |
| Identification number and letter for switching elements | | 22 E |
| Product extension / auxiliary switch | | Yes |
| Protection class IP / on the front | | IP20 |
| Protection against electrical shock | | finger-safe |
| Degree of pollution | | 3 |
| Insulation voltage / with degree of pollution 3 / rated value | V | 690 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Ambient temperature / during storage | °C | -55… +80 |
| Ambient temperature / during operating | °C | -25… +60 |
| Shock resistance | | |
| | | |
| | | 7,3g / 5 ms, 4,7g / 10 ms |
| | | |
| | | 11,4g / 5 ms, 7,3g / 10 ms |
| Impulse voltage resistance / rated value | kV | 6 |
| Mechanical operating cycles as operating time | | |
- of the contactor / typical
| | 30,000,000 |
- of the contactor with added auxiliary switch block / typical
| | 10,000,000 |
- of the contactor with added electronics-compatible auxiliary switch block / typical
| | 10,000,000 |
| |
| Control circuit: |
| Type of voltage / of the controlled supply voltage | | AC |
| Control supply voltage / 1 | | |
- at 50 Hz / for AC / rated value
| V | 230 |
- at 60 Hz / for AC / rated value
| V | 230 |
| Operating range factor control supply voltage rated value / of the magnet coil | | |
| | | 0.8… 1.1 |
| | | 0.85… 1.1 |
| Apparent pull-in power / of the solenoid / for AC | V·A | 37 |
| Apparent holding power / of the solenoid / for AC | V·A | 5.7 |
| Inductive power factor | | |
- with the pull-in power of the coil
| | 0.8 |
- with the pull-in power of the coil
| | 0.25 |
| Closing delay | | |
| | ms | 8… 33 |
| Opening delay | | |
| | ms | 6… 25 |
| Arcing time | s | 10… 15 |
| |
| Auxiliary circuit: |
| Contact reliability / of the auxiliary contacts | | 1 faulty switching per 100 million (17 V, 1 mA) |
| Number of NC contacts / for auxiliary contacts / instantaneous switching | | 2 |
| Number of NO contacts / for auxiliary contacts / instantaneous switching | | 2 |
| Operating current / of the auxiliary contacts / at AC-12 / maximum | A | 10 |
| Operating current / of the auxiliary contacts / at AC-15 | | |
| | A | 6 |
| | A | 3 |
| | A | 2 |
| | A | 1 |
| Operating current | | |
- of the auxiliary contacts / with 1 current path / at DC-12
| | |
| | A | 6 |
| | A | 3 |
| | A | 1 |
- with 2 current paths in series / at DC-12
| | |
| | A | 10 |
| | A | 10 |
| | A | 4 |
| | A | 2 |
| | A | 1.3 |
| | A | 0.65 |
- with 3 current paths in series / at DC-12
| | |
| | A | 10 |
| | A | 10 |
| | A | 10 |
| | A | 3.6 |
| | A | 2.5 |
| | A | 1.8 |
| Operating current | | |
- of the auxiliary contacts / with 1 current path / at DC-13
| | |
| | A | 6 |
| | A | 1 |
| | A | 0.3 |
- with 2 current paths in series / at DC-13
| | |
| | A | 10 |
| | A | 3.5 |
| | A | 1.3 |
| | A | 0.9 |
| | A | 0.2 |
| | A | 0.1 |
- with 3 current paths in series / at DC-13
| | |
| | A |
|