| | OVERLOAD RELAY 6...25 A FOR MOTOR PROTECTION SIZE S0, CLASS 10 CONTACTOR ASS. MAIN CIRCUIT: SCREW CONN. AUX.CIRCUIT: SCREW CONN. MANUAL-AUTOM.-RESET REUSABLE PACKAGING PACKAGE = XX ITEMS |
| |
| General technical data: |
| product brand name | | SIRIUS |
| product designation | | solid-state overload relay |
| Protection class IP / on the front | | IP20 |
| Insulation voltage / with degree of pollution 3 / rated value | V | 690 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Ambient temperature | | |
| | °C | -40… +80 |
| | °C | -40… +80 |
| | °C | -25… +60 |
| Relative humidity | | |
| | / % | 95 |
| EMC immunity to interference | | |
| | | corresponds to degree of severity 3 |
| EMC emitted interference | | |
| | | CISPR 11, environment B (residential area) |
| Conductor-bound parasitic coupling BURST | | |
- according to IEC 61000-4-4
| | 2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3 |
| Conductor-bound parasitic coupling conductor-earth SURGE | | |
- according to IEC 61000-4-5
| | 2 kV (line to earth) corresponds to degree of severity 3 |
| Conductor-bound parasitic coupling conductor-conductor SURGE | | |
- according to IEC 61000-4-5
| | 1 kV (line to line) corresponds to degree of severity 3 |
| Electrostatic discharge | | |
- according to IEC 61000-4-2
| | 6 kV contact discharge / 8 kV air discharge |
| Field-bound parasitic coupling | | |
- according to IEC 61000-4-3
| | 10 V/m |
| Resistance against shock | | 15g / 11 ms |
| Impulse voltage resistance / rated value | kV | 6 |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | F |
- according to DIN EN 61346-2
| | F |
| Size of overload relay | | S0 |
| Size of the contactor / can be combined / company-specific | | S0 |
| type of protection | | PTB 09 ATEX 3001 Ex II (2) GD |
| Type of assignement | | 2 |
| Trip class | | CLASS 10 |
| |
| Main circuit: |
| Number of poles / for main current circuit | | 3 |
| Operating voltage / at AC-3 / rated value | | |
| | V | 690 |
| Operating current / at AC-3 / at 400 V | | |
| | A | 25 |
| Adjustable response current | | |
- of the current-dependent overload release
| A | 6… 25 |
| Service power / for three-phase servomotors / at 400 V / at 50 Hz | | |
| | kW | 3… 11 |
| Operating current / of the fuse link | | |
| | A | 50 |
| |
| Auxiliary circuit: |
| Contact reliability / of the auxiliary contacts | | acceptability for PLC control (17 V, 5 mA) |
| Number of NC contacts / for auxiliary contacts | | 1 |
| Number of NO contacts / for auxiliary contacts | | 1 |
| Number of change-over switches / for auxiliary contacts | | 0 |
| Operating current / of the auxiliary contacts | | |
| | | |
| | A | 4 |
| | A | 4 |
| | A | 4 |
| | A | 4 |
| | A | 3 |
| | | |
| | A | 2 |
| | A | 1 |
| | A | 0.3 |
| | A | 0.3 |
| | A | 1 |
| |
| Short-circuit: |
| Design of the fuse link / for short-circuit protection of the auxiliary switch / required | | fuse gL/gG: 6 A |
| |
| Installation/mounting/dimensions: |
| Built in orientation | | any |
| Type of mounting | | direct mounting |
| Width | mm | 45 |
| Height | mm | 69.7 |
| Depth | mm | 83.5 |
| Distance, to be maintained, to the ranks assembly | | |
| | mm | 0 |
| | mm | 0 |
| | mm | 0 |
| | mm | 0 |
| | mm | 0 |
| Distance, to be maintained, to earthed part | | |
| | mm | 6 |
| | mm | 0 |
| | mm | 6 |
| | mm | 6 |
| | mm | 6 |
| Distance, to be maintained, conductive elements | | |
| | mm | Назад в раздел
|