| OVERLOAD RELAY 1...4 A FOR MOTOR PROTECTION SIZE S0, CLASS 10 CONTACTOR ASS. MAIN CIRCUIT: SCREW CONN. AUX.CIRCUIT: SCREW CONN. MANUAL-AUTOM.-RESET |
|
General technical data: |
product brand name | | SIRIUS |
product designation | | solid-state overload relay |
Protection class IP / on the front | | IP20 |
Insulation voltage / with degree of pollution 3 / rated value | V | 690 |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -40… +80 |
| °C | -40… +80 |
| °C | -25… +60 |
Relative humidity | | |
| / % | 95 |
EMC immunity to interference | | |
| | corresponds to degree of severity 3 |
EMC emitted interference | | |
| | CISPR 11, environment B (residential area) |
Conductor-bound parasitic coupling BURST | | |
- according to IEC 61000-4-4
| | 2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3 |
Conductor-bound parasitic coupling conductor-earth SURGE | | |
- according to IEC 61000-4-5
| | 2 kV (line to earth) corresponds to degree of severity 3 |
Conductor-bound parasitic coupling conductor-conductor SURGE | | |
- according to IEC 61000-4-5
| | 1 kV (line to line) corresponds to degree of severity 3 |
Electrostatic discharge | | |
- according to IEC 61000-4-2
| | 6 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling | | |
- according to IEC 61000-4-3
| | 10 V/m |
Resistance against shock | | 15g / 11 ms |
Impulse voltage resistance / rated value | kV | 6 |
Active power loss / total / typical | W | 0.05 |
Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | F |
- according to DIN EN 61346-2
| | F |
Size of overload relay | | S0 |
Size of the contactor / can be combined / company-specific | | S0 |
type of protection | | PTB 09 ATEX 3001 Ex II (2) GD |
Type of assignement | | 2 |
Trip class | | CLASS 10 |
|
Main circuit: |
Number of poles / for main current circuit | | 3 |
Operating voltage / at AC-3 / rated value | | |
| V | 690 |
Operating current / at AC-3 / at 400 V | | |
| A | 4 |
Adjustable response current | | |
- of the current-dependent overload release
| A | 1… 4 |
Service power / for three-phase servomotors / at 400 V / at 50 Hz | | |
| kW | 0.55… 1.5 |
Operating current / of the fuse link | | |
| A | 20 |
|
Auxiliary circuit: |
Contact reliability / of the auxiliary contacts | | acceptability for PLC control (17 V, 5 mA) |
Number of NC contacts / for auxiliary contacts | | 1 |
Number of NO contacts / for auxiliary contacts | | 1 |
Number of change-over switches / for auxiliary contacts | | 0 |
Operating current / of the auxiliary contacts | | |
| | |
| A | 4 |
| A | 4 |
| A | 4 |
| A | 4 |
| A | 3 |
| | |
| A | 2 |
| A | 1 |
| A | 0.3 |
| A | 0.3 |
| A | 1 |
|
Short-circuit: |
Design of the fuse link / for short-circuit protection of the auxiliary switch / required | | fuse gL/gG: 6 A |
|
Installation/mounting/dimensions: |
Built in orientation | | any |
Type of mounting | | direct mounting |
Width | mm | 45 |
Height | mm | 69.7 |
Depth | mm | 83.5 |
Distance, to be maintained, to the ranks assembly | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Distance, to be maintained, to earthed part | | |
| mm | 6 |
| mm | 0 |
| mm | 6 |
| mm | 6 |
| mm | 6 |
Distance, to be maintained, conductive elements | | |
|