3RB2113-4SD0 - OVERLOAD RELAY 3...12 A FOR MOTOR PROTECTION SIZE S00, CLASS 5...30 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SPRINGLOAD. TERM. MANUAL-AUTOMATIC-RESET INT. EARTH FAULT DETECTION (siemens) - Quad Industry GmbH

Артикул: 3RB2113-4SD0
Наименование: OVERLOAD RELAY 3...12 A FOR MOTOR PROTECTION SIZE S00, CLASS 5...30 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SPRINGLOAD. TERM. MANUAL-AUTOMATIC-RESET INT. EARTH FAULT DETECTION (siemens)
Производитель: Siemens


Наименование продукта
OVERLOAD RELAY 3...12 A FOR MOTOR PROTECTION SIZE S00, CLASS 5...30 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SPRINGLOAD. TERM. MANUAL-AUTOMATIC-RESET INT. EARTH FAULT DETECTION
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2006-02-28
    Версия от 2011-11-20
 
OVERLOAD RELAY 3...12 A FOR MOTOR PROTECTION SIZE S00, CLASS 5...30 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SPRINGLOAD. TERM. MANUAL-AUTOMATIC-RESET INT. EARTH FAULT DETECTION
 
General technical details:
Product brand name   SIRIUS
product designation   solid-state overload relay
Protection class IP / on the front   IP20
Insulation voltage / with degree of pollution 3 / rated value V 690
Adjustable response current    
  • of the current-dependent overload release
A 3 12
EMC emitted interference   degree of severity B according to EN 55011 (CISPR 11) and EN 55022 (CISPR 22)
Electrostatic discharge / according to IEC 61000-4-2   6 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / according to IEC 61000-4-3   10 V/m
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4   2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3
Conductor-bound parasitic coupling conductor-earth SURGE   2 kV (line to earth) corresponds to degree of severity 3
Conductor-bound parasitic coupling conductor-conductor SURGE   1 kV (line to line) corresponds to degree of severity 3
Resistance against shock   15g / 11 ms
Impulse voltage resistance / rated value kV 6
Active power loss / total / typical W 0.05
type of protection   PTB 06 ATEX 3001 Ex II (2) GD
Type of assignement   2
Trip class   CLASS 5, 10, 20 and 30 adjustable
Item designation    
  • according to DIN EN 61346-2
  F
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  F
Protection against electrical shock   finger-safe
 
Control circuit:
Design of the electrical connection / for auxiliary and control current circuit   spring-loaded terminals
 
Main circuit:
Number of poles / for main current circuit   3
Operating voltage / at AC-3 / rated value / maximum V 690
Operating current / of the fuse link    
  • rated value
A 20
Service power / for three-phase servomotors    
  • rated value
kW 1.1 5.5
Design of the electrical connection / for main current circuit   screw-type terminals
Service power / for three-phase servomotors / at 400 V / at 50 Hz    
  • for AC three-phase
kW 1.1 5.5
 
Auxiliary circuit:
Contact reliability / of the auxiliary contacts   acceptability for PLC control (17 V, 5 mA)
Operating current / of the auxiliary contacts    
  • at AC-15
   
  • at 24 V
A 4
  • at 110 V
A 4
  • at 120 V
A 4
  • at 125 V
A 4
  • at 230 V
A 3
  • at DC-13
   
  • at 24 V
A 2
  • at 60 V
A 0.55
  • at 110 V
A 0.3
  • at 125 V
A 0.3
  • at 220 V
A 0.11
Number of NC contacts   1
Number of NO contacts   1
Number of change-over switches   0
 
Short-circuit:
   
Design of the fuse link / for short-circuit protection of the auxiliary switch / required   fuse gL/gG: 6 A
 
Mechanical design:
Built in orientation   any
Type of mounting   direct mounting
Size of the contactor / can be combined / company-specific   S00
Size of overload relay   S00
Width mm 45
Height mm 64
Depth mm 73
Distance, to be maintained, to the ranks assembly    
  • upwards
mm 0
  • forwards
mm 0
  • sidewards
mm 0
  • backwards
mm 0
  • downwards
mm 0
Distance, to be maintained, to earthed part    
  • upwards
mm 0
  • forwards
mm 0
  • sidewards
mm 6
  • backwards
mm 0
  • downwards
mm 0
Distance, to be maintained, conductive elements    
  • upwards
mm 0
  • forwards
mm 0
  • sidewards
mm 6
  • backwards
mm 0
  • downwards
mm 0
 
Ambient conditions:
Ambient temperature    
  • during operating
°C -25 60
Ambient temperature    
  • during storage
°C -40 80
Ambient temperature    
  • during transport
°C -40Назад в раздел