3RA7112-1DA26-0AB4 - SIRIUS SI. LOAD FEEDER, 24V DC, S0, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 1.1KW, MOTOR CURRENT: 2.7A, TH. OVERLOAD COMP.:2.2..3.2A, (siemens) - Quad Industry GmbH
Артикул: 3RA7112-1DA26-0AB4
Наименование: SIRIUS SI. LOAD FEEDER, 24V DC, S0, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 1.1KW, MOTOR CURRENT: 2.7A, TH. OVERLOAD COMP.:2.2..3.2A, (siemens)
Производитель: Siemens
|
|
| | Наименование продукта SIRIUS SI. LOAD FEEDER, 24V DC, S0, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 1.1KW, MOTOR CURRENT: 2.7A, TH. OVERLOAD COMP.:2.2..3.2A, | | | | | SIRIUS SI. LOAD FEEDER, 24V DC, S0, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 1.1KW, MOTOR CURRENT: 2.7A, TH. OVERLOAD COMP.:2.2..3.2A, | | | | General technical details: | | Design of the product | | direct starter | | Operating current / at 400 V / for AC | | | | | A | 2.7 | | Breaking capacity current / at AC-3 | A | 2.7 | | Breaking capacity limit short-circuit current (lcu) / at 400 V | | | | | kA | 50 | | Adjustable response current | | | - of the current-dependent overload release
| A | 2.2… 3.2 | | type of voltage | | DC | | Supply voltage frequency / for auxiliary and control current circuit | | | | | Hz | 0… 0 | | Operating voltage / rated value | V | 400 | | Control supply voltage | | | | | V | 24… 24 | | Service power / at AC-3 / at 400 V | | | | | kW | 1.1 | | Type of assignement | | 2 | | Item designation | | | - according to DIN EN 61346-2
| | A | - according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | Q | | | | Mechanical design: | | Type of the safety-related wiring | | | | | | Yes | | | | Yes | | Design of the electrical connection | | | | | | screw-type terminals | | Design of the cascading | | yes | | Size of the load feeder | | S0 | | Width | mm | 90 | | Height | mm | 217 | | Depth | mm | 185 | | Product function | | | | | | Yes | | | | Yes | | | | Yes | | | | Yes | | | | No | | Suitability for interaction / pressing control | | No | | | | Protocols: | | | | Protocol / will be supported | | | | | | No | | | | No | | | | Certificates/approvals: | | | | General Product Approval | Functional Safety / Safety of Machinery | other | | ROSTEST | | | | | | | | | last change: | Mar 5, 2012 | |
|
Назад в раздел
|