| | FUNCTION MODULE FOR AS-I, STAR-DELTA START, SPRING-LOADED CONNECTION, MOUNTED ON CONTACTORS 3RT2 S00/ S0 COMM. CAPABLE CONTACTOR REQUIRED |
| |
| General technical data: |
| product brand name | | Sirius |
| product designation | | set star-delta (wye-delta) start AS-i spring-loaded terminal |
| Design of the product | | star-delta (wye-delta) starter function |
| Size of the contactor / can be combined / company-specific | | S00, S0 |
| Protection class IP / on the front | | IP20 |
| Degree of pollution | | 3 |
| Insulation voltage / with degree of pollution 3 | | |
| | V | 690 |
| Installation altitude / at a height over sea level / maximum | m | 2,000 |
| Ambient temperature | | |
| | °C | -40… +80 |
| | °C | -25… +60 |
| | °C | -40… +80 |
| EMC immunity to interference | | |
| | | ambience A (industrial sector) |
| EMC emitted interference | | |
| | | CISPR11, ambience A (industrial sector) |
| Conductor-bound parasitic coupling BURST | | |
- according to IEC 61000-4-4
| | 2 kV network connection / 1 kV control connection |
| Conductor-bound parasitic coupling conductor-earth SURGE | | |
- according to IEC 61000-4-5
| | 1 kV |
| Conductor-bound parasitic coupling conductor-conductor SURGE | | |
- according to IEC 61000-4-5
| | 0.5 kV |
| Electrostatic discharge | | |
- according to IEC 61000-4-2
| | 8 kV |
| Field-bound parasitic coupling | | |
- according to IEC 61000-4-3
| | 10 V/m |
| Resistance against shock | | 11g / 15 ms |
| Resistance against vibration | | 10 ... 55 Hz / 0.35 mm |
| Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | K |
- according to DIN EN 61346-2
| | K |
| Acceptability for application | | |
| | | No |
| | | Yes |
| | | No |
| |
| Communication: |
| Product function | | |
| | | Yes |
- control circuit interface with AS interface
| | Yes |
| |
| Control circuit: |
| Design of the surge suppressor | | suppressor diode |
| Type of voltage / of the controlled supply voltage | | DC |
| Control supply voltage / 1 / for DC / rated value | V | 24 |
| |
| |
| Installation/mounting/dimensions: |
| Built in orientation | | any |
| Type of mounting | | can be plugged into contactor |
| Width | mm | 45 |
| Height | mm | 39 |
| Depth | mm | 75 |
| |
| Connections: |
| Product function | | |
- removable terminal for auxiliary and control circuit
| | Yes |
| Design of the electrical connection | | |
- for auxiliary and control current circuit
| | spring-loaded terminals |
| Type of the connectable conductor cross-section | | |
| | | |
| | | 1x (0.25 ... 1.5 mm²), 2x (0.25 ... 1.5 mm²) |
| | | |
- with conductor end processing
| | 1x (0.25 ... 1.5 mm²), 2x (0.25 ... 1.5 mm²) |
- without conductor final cutting
| | 1x (0.25 ... 1.5 mm²), 2x (0.25 ... 1.5 mm²) |
- for AWG conductors / for auxiliary contacts
| | 2x (24 ... 16) |
| |
| Certificates/approvals: |
| Verification of suitability | | CE / UL / CSA |
| General Product Approval | Test Certificates | | | |
| | |
| | |
| |
| last change: | Feb 6, 2012 |