3RA1434-8XB20-1BB4 - CONTACTOR COMBINATION, STAR-DELTA (FACTORY-ASSEMBLED) WITH FRONT SIDE TIMING RELAY, AC-3 22/30 KW/400 V, 3-POLE, SIZE S2, S2, S0, EL. LOCKED, SCREW CONNECTION, 24 V DC, (siemens) - Quad Industry GmbH

Артикул: 3RA1434-8XB20-1BB4
Наименование: CONTACTOR COMBINATION, STAR-DELTA (FACTORY-ASSEMBLED) WITH FRONT SIDE TIMING RELAY, AC-3 22/30 KW/400 V, 3-POLE, SIZE S2, S2, S0, EL. LOCKED, SCREW CONNECTION, 24 V DC, (siemens)
Производитель: Siemens


Наименование продукта
CONTACTOR COMBINATION, STAR-DELTA (FACTORY-ASSEMBLED) WITH FRONT SIDE TIMING RELAY, AC-3 22/30 KW/400 V, 3-POLE, SIZE S2, S2, S0, EL. LOCKED, SCREW CONNECTION, 24 V DC,
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2001-01-01
CONTACTOR COMBINATION, STAR-DELTA (FACTORY-ASSEMBLED) WITH FRONT SIDE TIMING RELAY, AC-3 22/30 KW/400 V, 3-POLE, SIZE S2, S2, S0, EL. LOCKED, SCREW CONNECTION, 24 V DC,
 
General details:
Product brand name   SIRIUS
product designation   contactor assembly
Degree of pollution   3
Insulation voltage / with degree of pollution 3 / rated value V 690
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature    
  • during storage
°C -55 +80
  • during transport
°C -55 +80
Mechanical operating cycles as operating time    
  • of the main contacts / typical
  10,000,000
  • of the auxiliary contacts / typical
  10,000,000
  • of the contactor with added auxiliary switch block / typical
  10,000,000
 
Main circuit:
Number of poles / for main current circuit   3
Number of NC contacts / for main contacts   0
Operating voltage / at AC-3 / rated value / maximum V 690
 
Steuerstromkreis/Ansteuerung:
Design of activation   conventional
Design of the surge suppressor   without
Working range factor supply voltage rated value / of the magnet coil    
  • at 50 Hz
   
  • for AC
  0.8 1.1
  • at 60 Hz
   
  • for AC
  0.85 1.1
  • for DC
  0.8 1.1
 
Auxiliary circuit:
Product extension / auxiliary switch   Yes
Number of NC contacts / for auxiliary contacts    
  • lagging switching
  0
Number of NO contacts / for auxiliary contacts    
  • leading switching
  0
 
Short-circuit:
   
Design of the fuse link    
  • for short-circuit protection of the auxiliary switch / required
  fuse gL/gG: 10 A
  • for short-circuit protection of the main circuit
   
  • with type of assignment 1 / required
  fuse gL/gG: 125 A
  • at type of coordination 2 / required
  fuse gL/gG: 63 A
 
Einbau/Befestigung/Abmessung:
   
Built in orientation   with vertical mounting surface +/-180° rotatable, with vertical mounting surface +/- 30° tiltable to the front and back
Distance, to be maintained, to the ranks assembly / sidewards mm 0
Distance, to be maintained, to earthed part / sidewards mm 0
Distance, to be maintained, conductive elements    
  • sidewards
mm 0
 
 
Approbationen/ Zertifikate
   
Verification of suitability   CE / UL / CCC / GL / LRS / BV / DNV / RMRS / RINA / PRS / ABS
General Product Approval Shipping Approval
ROSTEST
 
 
last change:
Aug 22, 2011

Назад в раздел